AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 12

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P36C*+TDR+TXV+ furnace: A80UH2E110C20AHRI reference: 21173596715.608.50148002.22EPA 2466180 →
EAH1P36C*+TDR+TXV+ furnace: A93UH1E110C20AHRI reference: 21173614915.608.50148002.24EPA 2466188 →
EAH1P30A*+TDR+TXV+ furnace: A80US2V070A12AHRI reference: 21173590415.607.80139001.98EPA 2466196 →
EAH1P30A*+TDR+TXV+ furnace: A80US2V070A12LAHRI reference: 21173590715.607.80139001.98EPA 2466202 →
EAH1P36C*+TDR+TXV+ furnace: A80UH1E110C20AHRI reference: 21173608715.608.30146002.22EPA 2468837 →
EAD4X-42B+TDR+ furnace: A96DF1E070B16AHRI reference: 21326495615.608.60153002.32EPA 2839854 →
EAD4X-42B+TDR+ furnace: A80DS2V090B16AHRI reference: 21326495715.608.60153002.32EPA 2839857 →
EAD4X-42B+TDR+ furnace: A97DSMV070B12AHRI reference: 21326495815.608.60154002.32EPA 2839858 →
EAH1P36C*+TDR+TXV+ furnace: A98USMV090C16AHRI reference: 21380529115.608.30144002.22EPA 2856801 →
EAH1P36C*+TDR+TXV+ furnace: A98USMV090C12AHRI reference: 21380528915.608.30147002.22EPA 2856820 →
EAC4X30B+TDR+ furnace: A98USMV070B12AHRI reference: 21380520415.608.00145002.18EPA 2856904 →
EA(C;U)1P30A+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380503815.608.00145002.18EPA 2856919 →
EA(C;U)1P30B+TDR+TXV+ furnace: A98USMV070B12AHRI reference: 21380520215.608.00145002.18EPA 2857994 →
EA(C;U)1P30B+TDR+TXV+ furnace: A97US2V070B12SAHRI reference: 21407479415.608.00145002.18EPA 3392013 →
EA(C;U)1P36B+TDR+TXV+ furnace: A97US2V045B12SAHRI reference: 21407479515.608.10145002.26EPA 3392014 →
EAH1P36C+TDR+TXV+ furnace: A97US2V090C12SAHRI reference: 21407479615.608.30147002.22EPA 3392015 →
EAH1P36C+TDR+TXV+ furnace: A97US2V090C16SAHRI reference: 21407479715.608.30144002.22EPA 3392016 →
EAH1P36C+TDR+TXV+ furnace: A97US2V110C16SAHRI reference: 21407479915.608.30146002.22EPA 3392017 →
EAC4X30B+TDR+ furnace: A97US2V070B12SAHRI reference: 21407480215.608.00145002.18EPA 3392079 →
EAC4X36B+TDR+ furnace: A97US2V045B12SAHRI reference: 21407480315.608.10145002.26EPA 3392080 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →