AIREASE / AIR-SOURCE HEAT PUMP

4SHP17LE130P-**A

4HSP17LE Series · 4SHP17 SERIES · 4SHP17L SERIES · 4SHP17LE SERIES · 4SHP17LE Series · 4SHP17LE1 Series · source records, page 11

333 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4SHP17LE130P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 333 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2333 / 333
EER2 · BTU/Wh12.2–13.5333 / 333
HSPF2 · BTU/Wh7.8–8.6333 / 333
Cooling capacity · BTU/h28,200–30,600333 / 333
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000333 / 333
Heating capacity at 17°F / −8.3°C · BTU/h17,200–19,600333 / 333
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400333 / 333
COP at 5°F / −15°C1.96–2.38333 / 333
Equipment / loop typeHP - Split System333 / 333
Refrigerant / source-reported GWPR-410A (GWP:2088)333 / 333
Compressor stagingSingle stage333 / 333
Connected capabilityNo333 / 333

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30B+TDR+TXV+ furnace: A93UH1E070B12AHRI reference: 21166298915.608.00144002.20EPA 2458972 →
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH2E070A12AHRI reference: 21032996115.608.00144002.20EPA 2459087 →
EA(C;U)1P30B+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21166298715.608.00143002.20EPA 2459221 →
EA(C;U)1P30B+TDR+TXV+ furnace: A93UH1E045B12AHRI reference: 21166298815.608.00144002.20EPA 2459223 →
EA(C;U)1P30A+TDR+TXV+ furnace: A93UH1E030B12AHRI reference: 21032998115.608.00143002.20EPA 2459366 →
EA(C;U)1P30A+TDR+TXV+ furnace: A80US2V070A12LAHRI reference: 21032996915.608.00145002.20EPA 2459368 →
EA(C;U)1P30A+TDR+TXV+ furnace: A93UH1E070B12AHRI reference: 21032997415.608.00144002.20EPA 2459387 →
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E070A12AHRI reference: 21032996315.608.00144002.20EPA 2459411 →
EAC4X36B+TDR+ furnace: A96UH1E045B12AHRI reference: 21166308915.608.10146002.26EPA 2459486 →
EAC4X36B+TDR+ furnace: A96UH1E070B12AHRI reference: 21166309015.608.10143002.26EPA 2459488 →
EAC4X36B+TDR+ furnace: A96UH1E030B12AHRI reference: 21166308815.608.00143002.24EPA 2459489 →
EA(C;U)1P30A+TDR+TXV+ furnace: A80UH1E060A12XAHRI reference: 21032996515.607.80142002.20EPA 2459629 →
EAH1P36C*+TDR+TXV+ furnace: A93UH1E090C16AHRI reference: 21173611815.608.30146002.24EPA 2462794 →
EAH1P36C*+TDR+TXV+ furnace: A96UH1E090C16AHRI reference: 21173616315.608.30145002.22EPA 2464092 →
EAH1P36C*+TDR+TXV+ furnace: A97USMV090C16AHRI reference: 21173622315.608.30144002.22EPA 2464102 →
EAH1P36C*+TDR+TXV+ furnace: A96UH1E110C20AHRI reference: 21173617715.608.50148002.26EPA 2464925 →
EAH1P36C*+TDR+TXV+ furnace: A80US2V080C20XAHRI reference: 21173618115.608.50150002.24EPA 2465318 →
EAH1P36C*+TDR+TXV+ furnace: A93UH1E090C12AHRI reference: 21173610215.608.30147002.24EPA 2465324 →
EAH1P36C*+TDR+TXV+ furnace: A97US2V080C16XAHRI reference: 21173621215.608.30146002.20EPA 2465333 →
EAH1P36C*+TDR+TXV+ furnace: A97USMV090C12AHRI reference: 21173621915.608.30147002.22EPA 2465334 →