ACIQ / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 4

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17249 / 249
EER2 · BTU/Wh11.7–13249 / 249
HSPF2 · BTU/Wh7.8–8.5249 / 249
Cooling capacity · BTU/h33,800–37,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200249 / 249
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600249 / 249
COP at 5°F / −15°C1.78–2.48249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingTwo-stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663125415.507.80178001.78EPA 3960713
EVD5X48M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663125015.507.80177001.80EPA 3960714
EVD5X48M21A*+ furnace: *96VTN1002122B*AHRI reference: 21663126715.507.80176001.80EPA 3960715
EA*5X37M17A*+ furnace: *80VSL0901716B*AHRI reference: 21663206015.508.10189002.28EPA 3961534
EA*5X37M17A*+ furnace: *80CSU0401712A*AHRI reference: 21663205515.508.10189002.28EPA 3961541
EA*5X37M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663206215.508.10188002.28EPA 3961544
EA*5X37M17A*+ furnace: *80MSU0401712A*AHRI reference: 21663206115.508.10188002.26EPA 3961546
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21663208915.508.10193002.26EPA 3961813
EA*5X37M21A*+ furnace: *80MSU0802120A*AHRI reference: 21663209415.508.10191002.42EPA 3961814
EA*5X37M21A*+ furnace: *80MSU0401712A*AHRI reference: 21663209215.508.10193002.26EPA 3961815
EA*5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21663209515.508.10194002.26EPA 3961818
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663209015.508.10193002.26EPA 3961820
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663210015.508.10193002.26EPA 3961821
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663210315.508.10193002.26EPA 3961823
EA*5X37M21A*+ furnace: *80CTL0702120B*AHRI reference: 21663209815.508.10194002.24EPA 3961824
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21663210115.508.10193002.24EPA 3961825
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 21663209915.508.10194002.24EPA 3961826
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663210415.508.10195002.24EPA 3961828
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663210715.508.10193002.24EPA 3961830
EA*5X37M21A*+ furnace: *96VSN1002120B*AHRI reference: 21663211615.508.10194002.26EPA 3961831

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →