ACIQ / AIR-SOURCE HEAT PUMP

N5H8T36*K*AAA*

2-STAGE 18 SEER HP · source records, page 3

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,800–37,600BTU/h

Each efficiency range summarizes published EPA records for N5H8T36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17249 / 249
EER2 · BTU/Wh11.7–13249 / 249
HSPF2 · BTU/Wh7.8–8.5249 / 249
Cooling capacity · BTU/h33,800–37,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h37,200–39,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h23,000–24,200249 / 249
Heating capacity at 5°F / −15°C · BTU/h17,500–19,600249 / 249
COP at 5°F / −15°C1.78–2.48249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)249 / 249
Compressor stagingTwo-stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21663114415.507.80177001.78EPA 3960678
EVD5X38M17A*+ furnace: *80CSU0401712A*AHRI reference: 21663116415.507.80178001.80EPA 3960680
EVD5X37M21A*+ furnace: *96VTN1002122B*AHRI reference: 21663116315.507.80176001.80EPA 3960682
EVD5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21663115815.507.80178001.78EPA 3960683
EVD5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663115115.507.80178001.78EPA 3960687
EVD5X38M17A*+ furnace: *96VSN0801716B*AHRI reference: 21663118015.507.80179001.80EPA 3960690
EVD5X38M17A*+ furnace: *80CTL0701716B*AHRI reference: 21663117315.507.80177001.78EPA 3960691
EVD5X38M17A*+ furnace: *80VTL0701716B*AHRI reference: 21663117515.507.80177001.80EPA 3960693
EVD5X38M17A*+ furnace: *80VSL0701716B*AHRI reference: 21663116715.507.80177001.78EPA 3960694
EVD5X38M17A*+ furnace: *97CMN0801714B*AHRI reference: 21663117815.507.80179001.78EPA 3960698
EVD5X38M17A*+ furnace: *95MSU0601716A*AHRI reference: 21663118115.507.80178001.78EPA 3960699
EVD5X38M17A*+ furnace: *96CTN0801714B*AHRI reference: 21663118215.507.80178001.80EPA 3960700
EVD5X48M21A*+ furnace: *80VSL1102122B*AHRI reference: 21663124215.507.80177001.78EPA 3960702
EVD5X38M17A*+ furnace: *96VTN0801716B*AHRI reference: 21663118415.507.80179001.80EPA 3960703
EVD5X48M21A*+ furnace: *80CSU0802120A*AHRI reference: 21663123815.507.80176001.78EPA 3960704
EVD5X48M21A*+ furnace: *80VSL0902120B*AHRI reference: 21663124115.507.80177001.80EPA 3960705
EVD5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 21663126215.507.80178001.78EPA 3960708
EVD5X48M21A*+ furnace: *80VTL0902120B*AHRI reference: 21663125215.507.80177001.80EPA 3960709
EVD5X48M21A*+ furnace: *80MSU0601716A*AHRI reference: 21663124315.507.80177001.78EPA 3960710
EVD5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21663124415.507.80175001.80EPA 3960711

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →