AC PRO / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 2

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC60CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471011415.608.30252002.38EPA 3495175
7EC60CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471011515.608.30252002.38EPA 3495176
7EC49CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471008415.608.10250002.26EPA 3495308
EAC4X49C+TDR+ furnace: 80G2UH110CE16AHRI reference: 21032762415.408.10254002.26EPA 2455795
EA(C;U)1P60C+TDR+TXV+ furnace: 92G1UH110CE16AHRI reference: 21032757315.408.10252002.36EPA 2455799
BCE7E48M*4XAHRI reference: 21032753815.408.50244002.34EPA 2455876
EAC4X60C+TDR+ furnace: 96G1UH090CE16AHRI reference: 21032763815.408.10254002.36EPA 2455891
EAC4X49C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032761815.408.10254002.26EPA 2455896
EAC4X49C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032761615.408.10250002.24EPA 2455900
EAC4X49C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032761915.408.10254002.26EPA 2456128
EAC4X60C+TDR+ furnace: 96G1UH110CE20AHRI reference: 21032762915.408.10252002.34EPA 2457000
EA(C;U)1P49C+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21032756015.408.10254002.26EPA 2457407
EA(C;U)1P48C+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21032754415.408.10244002.18EPA 2457585
EA(C;U)1P49C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032755415.408.10254002.26EPA 2457685
EAC4X48C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032760815.408.10244002.18EPA 2458165
EA(C;U)1P60C+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21032757115.408.30254002.32EPA 2458176
EA(C;U)1P60C+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21032756515.408.10252002.34EPA 2458766
EAC4X60C+TDR+ furnace: 80G1UH110CE20AHRI reference: 21032763415.408.30254002.34EPA 2459022
EAC4X48C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032760715.408.10244002.22EPA 2459064
EAC4X60C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21032763715.408.10252002.36EPA 2459268

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →