AC PRO / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X48C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032760515.608.10242002.20EPA 2455796 →
EAC4X60C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032762815.608.10252002.38EPA 2455893 →
EA(C;U)1P60C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032756815.608.30252002.38EPA 2456987 →
EAC4X49C+TDR+ furnace: 80G1UH090CE20AHRI reference: 21032761515.608.10250002.26EPA 2456996 →
EAC4X60C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032763215.608.30252002.38EPA 2457683 →
EAC4X60C+TDR+ furnace: 80G2UH110CE20AHRI reference: 21032763115.608.30252002.38EPA 2457687 →
EA(C;U)1P48C+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21032754215.608.10242002.20EPA 2458804 →
EA(C;U)1P49C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21032755115.608.10250002.26EPA 2458918 →
EAC4X48C+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21032760615.608.10242002.20EPA 2459058 →
EA(C;U)1P48C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032754115.608.10242002.20EPA 2459061 →
EAC4X60C+TDR+ furnace: 80G2UH110CE16AHRI reference: 21032763915.608.30252002.36EPA 2459259 →
EA(C;U)1P60C+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21032756715.608.30252002.38EPA 2459308 →
EA(C;U)1P60C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21032756415.608.10252002.38EPA 2459586 →
EA(C;U)1P60C+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21032757515.608.30252002.36EPA 2461158 →
EAH1P51C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173725515.608.30252002.30EPA 2468887 →
7EH51CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471003115.608.30252002.30EPA 3484821 →
7EC60CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471011315.608.30252002.36EPA 3484913 →
7EC48CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471005815.608.10242002.20EPA 3495079 →
7EC48CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471005915.608.10242002.20EPA 3495080 →
7EC60CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471012115.608.10252002.38EPA 3495135 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →