AC PRO / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 12

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032769815.807.80174002.10EPA 2457884
EAC4X36B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032779315.807.80170002.12EPA 2457891
EAC4X50/60C+TDR+ furnace: 80G2UH110CV20AHRI reference: 21032781415.807.80174002.10EPA 2457901
EAC4X36A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21032777615.807.80170002.08EPA 2458993
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G2UH110CV20AHRI reference: 21032773015.807.80174002.10EPA 2459307
EA(C;U)1P36B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032771115.807.80170002.12EPA 2459885
EAH1P48B*+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21173626915.807.80172002.18EPA 2465747
EAH1P48B*+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21173629315.807.80172002.18EPA 2466652
EAH1P48B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173651515.808.00176002.22EPA 2469304
EAD4X-30/36C+TDR+ furnace: 92G1DF090CE16AHRI reference: 21326522215.808.00187002.14EPA 2839686
EAD4X-30/36C+TDR+ furnace: 96G1DF110CE20AHRI reference: 21326522415.808.10189002.12EPA 2839741
EAD4X-30/36B+TDR+ furnace: 80G1DF090BE16AHRI reference: 21326521415.808.00187002.14EPA 2839799
7EH48BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470971515.807.80172002.18EPA 3491795
7EH42BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470967315.808.00183002.20EPA 3491797
7EC50/60CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21470984415.807.80176002.12EPA 3491858
7EH48BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21470971715.807.80172002.18EPA 3494777
7EC36AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21470978315.807.80170002.08EPA 3494778
7EC36AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21470978415.807.80170002.08EPA 3494783
7EH42BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21470969015.808.00186002.24EPA 3494818
7EC36BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470980215.807.80172002.06EPA 3494861

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →