AC PRO / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 11

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED48CX-0*+TDR+ furnace: 97G2DF090CE16AHRI reference: 21470977416.008.60192002.32EPA 3495234
7ED48CX-0*+TDR+ furnace: 97G2DF110CE20AHRI reference: 21470977616.008.60190002.26EPA 3495237
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470968216.008.10184002.24EPA 3495288
7EH42BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470968316.008.10184002.24EPA 3495289
7AH2AE42PX-0*AHRI reference: 21486552416.008.30181002.36EPA 3553781
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21032769515.807.80170002.08EPA 2455789
EA(C;U)1P50/60C+TDR+TXV+ furnace: 95G1UH080CE16XAHRI reference: 21032772715.807.80172002.10EPA 2455790
BCE5V36M*4XAHRI reference: 21032768915.808.10174002.20EPA 2455845
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G1UH100CE20XAHRI reference: 21032772115.807.80176002.12EPA 2455848
EAC4X50/60C+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21032780515.807.80176002.12EPA 2455851
EAC4X36B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032779215.807.80170002.08EPA 2455880
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032771015.807.80170002.08EPA 2455921
EAC4X36B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032779115.807.80173002.10EPA 2456030
EAC4X36B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032778415.807.80170002.08EPA 2456046
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032770215.807.80170002.08EPA 2456997
EA(C;U)1P36B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032770915.807.80173002.10EPA 2457008
EAC4X36A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032777915.807.80174002.10EPA 2457661
EAC4X36A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032777715.807.80170002.08EPA 2457666
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21032769615.807.80170002.08EPA 2457671
EAC4X50/60C+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21032781115.807.80172002.10EPA 2457689

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →