Metric or attributeSource value
SEER2 · BTU/Wh17.50
EER2 · BTU/Wh11.00
HSPF2 · BTU/Wh8.50
Cooling capacity · BTU/h34000
Heating capacity at 47°F / 8.3°C · BTU/h34000
Heating capacity at 17°F / −8.3°C · BTU/h33600
Heating capacity at 5°F / −15°C · BTU/h28000
COP at 5°F / −15°C2.32
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingTwo-stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitHH836E2S12
+
Indoor unitCTM36C5CDS2+JME12C2SN2

AHRI reference 218643818 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for HH836E2S12

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4666357EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.32EPA Sep 21, 2026
eer2 btu wh11.00EPA Sep 21, 2026
series nameLX SERIESEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh8.50EPA Sep 21, 2026
model numberHH836E2S12EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh17.50EPA Sep 21, 2026
date certified2026-07-15T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingTwo-stageEPA Sep 21, 2026
energy star partnerJohnson Controls, Inc.EPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218643818EPA Sep 21, 2026
cooling capacity btu h34000EPA Sep 21, 2026
outdoor unit brand nameFraser-JohnstonEPA Sep 21, 2026
date available on market2026-07-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCTM36C5CDS2+JME12C2SN2EPA Sep 21, 2026
energy star model identifierES_21045_HH836E2S12_07012026203057_28218643818EPA Sep 21, 2026
heating capacity at 5 f btu h28000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h33600EPA Sep 21, 2026
heating capacity at 47 f btu h34000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026