BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

37MUHAQ36AA3+KSAIC0701230

Crossover Heat Pump · EPA record 4628008

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4628008. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh10.00
HSPF2 · BTU/Wh8.50
Cooling capacity · BTU/h36200
Heating capacity at 47°F / 8.3°C · BTU/h38000
Heating capacity at 17°F / −8.3°C · BTU/h25000
Heating capacity at 5°F / −15°C · BTU/h30200
COP at 5°F / −15°C1.84
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit37MUHAQ36AA3+KSAIC0701230
+
Indoor unitCAA**3721AM*
+
Required furnace8(0,1)*SB60110M21***

AHRI reference 218480745 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 37MUHAQ36AA3+KSAIC0701230

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4628008EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.84EPA Sep 21, 2026
eer2 btu wh10.00EPA Sep 21, 2026
series nameCrossover Heat PumpEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh8.50EPA Sep 21, 2026
model number37MUHAQ36AA3+KSAIC0701230EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2026-06-16T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number8(0,1)*SB60110M21***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218480745EPA Sep 21, 2026
cooling capacity btu h36200EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2025-05-06T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAA**3721AM*EPA Sep 21, 2026
energy star model identifierES_1020846_37MUHAQ36AA3+KSAIC0701230_06052026150320_28218480745EPA Sep 21, 2026
heating capacity at 5 f btu h30200EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h25000EPA Sep 21, 2026
heating capacity at 47 f btu h38000EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026