Amana / AIR-SOURCE HEAT PUMP

AZV9SA361CA*

AZV9SA · EPA record 4497803

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4497803. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh18.20
EER2 · BTU/Wh11.00
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h33400
Heating capacity at 47°F / 8.3°C · BTU/h31000
Heating capacity at 17°F / −8.3°C · BTU/h30800
Heating capacity at 5°F / −15°C · BTU/h31000
COP at 5°F / −15°C2.00
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityYes

Open original source record ↗

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV9SA361CA*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight230 lbAZV9S S-Series — product specifications · page 3
Maximum overcurrent protection25 AAZV9S S-Series — product specifications · page 3
Minimum circuit ampacity21.8 AAZV9S S-Series — product specifications · page 3
Shipping weight265 lbAZV9S S-Series — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseAZV9S S-Series — product specifications · page 3

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitAZV9SA361CA*
+
Indoor unitCHPEA4830*3A*+MBVK16CP0X00A*

AHRI reference 217589473 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for AZV9SA361CA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4497803EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.00EPA Sep 21, 2026
dr protocolOpenADREPA Sep 21, 2026
eer2 btu wh11.00EPA Sep 21, 2026
series nameAZV9SAEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model numberAZV9SA361CA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh18.20EPA Sep 21, 2026
connects usingWi-FiEPA Sep 21, 2026
date certified2026-01-06T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerDaikin Comfort Technologies Manufacturing, L.P.EPA Sep 21, 2026
connected capabilityYesEPA Sep 21, 2026
refrigerant with gwpR-32 (GWP:675 | Lower GWP)EPA Sep 21, 2026
ahri reference number217589473EPA Sep 21, 2026
cooling capacity btu h33400EPA Sep 21, 2026
outdoor unit brand nameAmanaEPA Sep 21, 2026
date available on market2025-07-10T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCHPEA4830*3A*+MBVK16CP0X00A*EPA Sep 21, 2026
installation capabilitiesAutomatic system discovery,Test mode for manual measurements,Preprogrammed system tests,Airflow measurement or external static pressureEPA Sep 21, 2026
energy star model identifierES_1035638_AZV9SA361CA*_07102025013137_28217589473EPA Sep 21, 2026
heating capacity at 5 f btu h31000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h30800EPA Sep 21, 2026
heating capacity at 47 f btu h31000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
communication hardware architectureA - Built-inEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026
broadband connection needed for demand responseYesEPA Sep 21, 2026