Each efficiency range summarizes published EPA records for AZV9SA361CA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.9–21 | 33 / 33 |
| EER2 · BTU/Wh | 11–12 | 33 / 33 |
| HSPF2 · BTU/Wh | 8.5–10 | 33 / 33 |
| Cooling capacity · BTU/h | 33,400–34,200 | 33 / 33 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,000–34,200 | 33 / 33 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,800–34,200 | 33 / 33 |
| Heating capacity at 5°F / −15°C · BTU/h | 31,000–34,200 | 33 / 33 |
| COP at 5°F / −15°C | 2–2.4 | 33 / 33 |
| Equipment / loop type | HP - Split System | 33 / 33 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 33 / 33 |
| Compressor staging | Continuously variable | 33 / 33 |
| Connected capability | Yes | 33 / 33 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Manufacturer specifications
These values match the manufacturer’s exact model pattern AZV9SA361CA*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.
| Specification | Value | Manufacturer evidence |
|---|---|---|
| Equipment weight | 230 lb | AZV9S S-Series — product specifications · page 3 ↗ |
| Maximum overcurrent protection | 25 A | AZV9S S-Series — product specifications · page 3 ↗ |
| Minimum circuit ampacity | 21.8 A | AZV9S S-Series — product specifications · page 3 ↗ |
| Shipping weight | 265 lb | AZV9S S-Series — product specifications · page 3 ↗ |
| Voltage / phase at 60 Hz | 208-230/1 V / phase | AZV9S S-Series — product specifications · page 3 ↗ |
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 216699794 | 21.00 | 10.00 | 34200 | 2.40 | EPA 3894062 → |
AHVE60DP1300A*Cold climate designationAHRI reference: 216699865 | 19.00 | 9.20 | 33000 | 2.10 | EPA 3894035 → |
AHVE60DP0300A*Cold climate designationAHRI reference: 216699866 | 19.00 | 9.20 | 33000 | 2.10 | EPA 3894036 → |
AHVE48DP1300A*Cold climate designationAHRI reference: 216699867 | 19.00 | 9.20 | 33000 | 2.10 | EPA 3894037 → |
AHVE48DP0300A*Cold climate designationAHRI reference: 216699868 | 19.00 | 9.20 | 33000 | 2.10 | EPA 3894038 → |
AHVE48CP1300A*Cold climate designationAHRI reference: 216699869 | 19.00 | 9.20 | 33000 | 2.10 | EPA 3894039 → |
AHVE48CP0300A*Cold climate designationAHRI reference: 216699870 | 19.00 | 9.20 | 33000 | 2.10 | EPA 3894040 → |
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 216699872 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894042 → |
CA*EA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 216699874 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894044 → |
CA*EA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 216699876 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894046 → |
CA*EA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 216699878 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894048 → |
CA*EA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 216699880 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894050 → |
CA*EA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 216699882 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894053 → |
CA*EA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 216699884 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894054 → |
CA*EA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 216699886 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894056 → |
CA*EA6030*3A*+ furnace: A*VM970804CNA*Cold climate designationAHRI reference: 216699888 | 19.00 | 9.20 | 32600 | 2.00 | EPA 3894058 → |
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 217589474 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4497802 → |
CA*EA6030*3A*+ furnace: A*VT800604B*A*Cold climate designationAHRI reference: 217883097 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4512524 → |
CA*EA6030*3A*+ furnace: A*VM970803BNA*Cold climate designationAHRI reference: 217883100 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4512525 → |
CA*EA6030*3A*+ furnace: A*VS800604BUA*Cold climate designationAHRI reference: 217883102 | 19.00 | 9.20 | 32600 | 2.00 | EPA 4512527 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
AZV9S S-Series — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values
Collection method, revision history and known limitations →