Amana / AIR-SOURCE HEAT PUMP

AZV7SA6010A*

AZV7SA · EPA record 3996749

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3996749. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh9.80
HSPF2 · BTU/Wh8.50
Cooling capacity · BTU/h52000
Heating capacity at 47°F / 8.3°C · BTU/h52500
Heating capacity at 17°F / −8.3°C · BTU/h33400
Heating capacity at 5°F / −15°C · BTU/h45000
COP at 5°F / −15°C1.80
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityYes

Open original source record ↗

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV7SA6010A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight236 lbAZV7S S-SERIES — product specifications · page 3
Maximum overcurrent protection40 AAZV7S S-SERIES — product specifications · page 3
Minimum circuit ampacity34.4 AAZV7S S-SERIES — product specifications · page 3
Shipping weight271 lbAZV7S S-SERIES — product specifications · page 3
Voltage / phase at 60 Hz208-230/1 V / phaseAZV7S S-SERIES — product specifications · page 3

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitAZV7SA6010A*
+
Indoor unitCHPEA6030*3A*
+
Required furnaceA*VT961005DNA*

AHRI reference 216835129 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for AZV7SA6010A*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3996749EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.80EPA Sep 21, 2026
dr protocolOpenADREPA Sep 21, 2026
eer2 btu wh9.80EPA Sep 21, 2026
series nameAZV7SAEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh8.50EPA Sep 21, 2026
model numberAZV7SA6010A*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
connects usingWi-FiEPA Sep 21, 2026
date certified2026-01-06T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerDaikin Comfort Technologies Manufacturing, L.P.EPA Sep 21, 2026
connected capabilityYesEPA Sep 21, 2026
furnace model numberA*VT961005DNA*EPA Sep 21, 2026
refrigerant with gwpR-32 (GWP:675 | Lower GWP)EPA Sep 21, 2026
ahri reference number216835129EPA Sep 21, 2026
cooling capacity btu h52000EPA Sep 21, 2026
outdoor unit brand nameAmanaEPA Sep 21, 2026
date available on market2025-03-10T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCHPEA6030*3A*EPA Sep 21, 2026
energy star model identifierES_1035638_AZV7SA6010A*_02102025104127_28216835129EPA Sep 21, 2026
heating capacity at 5 f btu h45000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h33400EPA Sep 21, 2026
heating capacity at 47 f btu h52500EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
communication hardware architectureA - Built-inEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026
broadband connection needed for demand responseYesEPA Sep 21, 2026