Amana / AIR-SOURCE HEAT PUMP

AZV7SA6010A*

AZV7SA

37 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity52,000BTU/h

Each efficiency range summarizes published EPA records for AZV7SA6010A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 37 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1837 / 37
EER2 · BTU/Wh9.837 / 37
HSPF2 · BTU/Wh8.5–937 / 37
Cooling capacity · BTU/h52,00037 / 37
Heating capacity at 47°F / 8.3°C · BTU/h52,500–54,00037 / 37
Heating capacity at 17°F / −8.3°C · BTU/h33,40037 / 37
Heating capacity at 5°F / −15°C · BTU/h45,000–46,00037 / 37
COP at 5°F / −15°C1.8–237 / 37
Equipment / loop typeHP - Split System37 / 37
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)37 / 37
Compressor stagingContinuously variable37 / 37
Connected capabilityYes37 / 37

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Manufacturer specifications

These values match the manufacturer’s exact model pattern AZV7SA6010A*. They describe the unit, separately from the EPA system ratings. For electrical work, the specification sheet requires checking the installed unit’s rating plate and its full instructions.

SpecificationValueManufacturer evidence
Equipment weight236 lbAZV7S S-SERIES — product specifications · page 3 ↗
Maximum overcurrent protection40 AAZV7S S-SERIES — product specifications · page 3 ↗
Minimum circuit ampacity34.4 AAZV7S S-SERIES — product specifications · page 3 ↗
Shipping weight271 lbAZV7S S-SERIES — product specifications · page 3 ↗
Voltage / phase at 60 Hz208-230/1 V / phaseAZV7S S-SERIES — product specifications · page 3 ↗

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
AHVE60DP1300A*Cold climate designationAHRI reference: 21683506618.009.00460002.00EPA 3996741 →
AHVE60DP0300A*Cold climate designationAHRI reference: 21683510718.009.00460002.00EPA 3996742 →
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21683511417.008.80460002.00EPA 3996744 →
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21683511917.008.80460002.00EPA 3996746 →
CA*EA6030*3A*+ furnace: A*VT801005C*A*Cold climate designationAHRI reference: 21683514717.008.80460002.00EPA 3996756 →
CA*EA6030*3A*+ furnace: A*VT800805D*A*Cold climate designationAHRI reference: 21683515117.008.80460002.00EPA 3996758 →
CA*EA6030*3A*+ furnace: A*VT800805C*A*Cold climate designationAHRI reference: 21683515617.008.80460002.00EPA 3996760 →
CA*EA6030*3A*+ furnace: A*VT800804C*A*Cold climate designationAHRI reference: 21683516117.008.80460002.00EPA 3996762 →
CA*EA6030*3A*+ furnace: A*VS800805CUA*Cold climate designationAHRI reference: 21683516717.008.80460002.00EPA 3996764 →
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21683518017.008.80460002.00EPA 3996769 →
CA*EA6030*3A*+MBVK20DP0X00A*Cold climate designationAHRI reference: 21758947617.008.80460002.00EPA 4497804 →
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758947817.008.80460002.00EPA 4497811 →
CA*EA6030*3A*+ furnace: A*VT961005CNA*Cold climate designationAHRI reference: 21683513816.508.50460002.00EPA 3996752 →
CA*EA6030*3A*+ furnace: A*VT960804CNA*Cold climate designationAHRI reference: 21683514216.508.80460002.00EPA 3996754 →
CA*EA6030*3A*+ furnace: A*VM971005CNA*Cold climate designationAHRI reference: 21683517816.508.80460002.00EPA 3996768 →
CA*EA6030*3A*+ furnace: A*VS960805CUA*Cold climate designationAHRI reference: 21749590716.508.80460002.00EPA 4469776 →
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21683510916.008.50450001.80EPA 3996743 →
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21683511616.008.50450001.80EPA 3996745 →
CHPEA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 21683512316.008.50450001.80EPA 3996747 →
CA*EA6030*3A*+ furnace: A*VT961205DNA*Cold climate designationAHRI reference: 21683512516.008.50460002.00EPA 3996748 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

AZV7S S-SERIES — product specifications ↗ — Manufacturer family specification sheet; only explicitly matched model patterns receive extracted values

Collection method, revision history and known limitations →