Carrier / AIR-SOURCE HEAT PUMP

27TPA860A**30*

2-STAGE 18 SEER HP · EPA record 3951922

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3951922. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh11.70
HSPF2 · BTU/Wh8.00
Cooling capacity · BTU/h56000
Heating capacity at 47°F / 8.3°C · BTU/h57500
Heating capacity at 17°F / −8.3°C · BTU/h36800
Heating capacity at 5°F / −15°C · BTU/h30200
COP at 5°F / −15°C2.25
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingTwo-stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit27TPA860A**30*
+
Indoor unitCAA**6124AM*
+
Required furnaceGG96VTAB60100C**

AHRI reference 215630415 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 27TPA860A**30*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3951922EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.25EPA Sep 21, 2026
eer2 btu wh11.70EPA Sep 21, 2026
series name2-STAGE 18 SEER HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh8.00EPA Sep 21, 2026
model number27TPA860A**30*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2025-02-17T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingTwo-stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberGG96VTAB60100C**EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number215630415EPA Sep 21, 2026
cooling capacity btu h56000EPA Sep 21, 2026
outdoor unit brand nameCarrierEPA Sep 21, 2026
date available on market2024-11-04T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAA**6124AM*EPA Sep 21, 2026
energy star model identifierES_1020846_27TPA860A**30*_09172024015634_7872292EPA Sep 21, 2026
heating capacity at 5 f btu h30200EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h36800EPA Sep 21, 2026
heating capacity at 47 f btu h57500EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026