Carrier / AIR-SOURCE HEAT PUMP

27TPA860A**30*

2-STAGE 18 SEER HP · EPA record 3951207

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 3951207. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh11.70
HSPF2 · BTU/Wh8.00
Cooling capacity · BTU/h54500
Heating capacity at 47°F / 8.3°C · BTU/h57000
Heating capacity at 17°F / −8.3°C · BTU/h36400
Heating capacity at 5°F / −15°C · BTU/h29800
COP at 5°F / −15°C2.25
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingTwo-stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit27TPA860A**30*
+
Indoor unitCAA**6024AM*
+
Required furnace59SP6B120V24**22

AHRI reference 215629331 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 27TPA860A**30*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id3951207EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.25EPA Sep 21, 2026
eer2 btu wh11.70EPA Sep 21, 2026
series name2-STAGE 18 SEER HPEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh8.00EPA Sep 21, 2026
model number27TPA860A**30*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2025-02-17T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingTwo-stageEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number59SP6B120V24**22EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number215629331EPA Sep 21, 2026
cooling capacity btu h54500EPA Sep 21, 2026
outdoor unit brand nameCarrierEPA Sep 21, 2026
date available on market2024-11-04T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAA**6024AM*EPA Sep 21, 2026
energy star model identifierES_1020846_27TPA860A**30*_09172024014921_8350984EPA Sep 21, 2026
heating capacity at 5 f btu h29800EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h36400EPA Sep 21, 2026
heating capacity at 47 f btu h57000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026