A model may have several rated combinations.
KERRAir-source heat pump

A-series

A-KCD18SA-1

3 published source records

16.1–18SEER2 range
9.3–9.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KCD24SA-1

3 published source records

16.5–17.4SEER2 range
9.5–10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KCD30SA-1

4 published source records

15.2–16.2SEER2 range
8.5–9.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KCD36SA-1

4 published source records

15.2–16SEER2 range
8.6–10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KCD48SA-1

2 published source records

15.6SEER2 range
9.4HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KCD60SA-1

2 published source records

15.3SEER2 range
9.4HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KHP06SA-1

3 published source records

22–25.5SEER2 range
12–14.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KHP09SA-1

8 published source records

20.5–27.4SEER2 range
10.9–13.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KHP12SA-1

5 published source records

20–25.4SEER2 range
10–11.6HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A-KHP Series

A-KHP183A-1

3 published source records

20–25SEER2 range
10–10.4HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

KERRAir-source heat pump

Multiple source series

A-KHP18SA-1

7 published source records

18–21.4SEER2 range
10–12.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KHP24SA-1

5 published source records

18.7–21SEER2 range
10–13.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A-KHP Series

A-KHP284A-1

3 published source records

19–23SEER2 range
9.5–10.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

KERRAir-source heat pump

A-KHP Series

A-KHP33SA-1

2 published source records

16.5–19.5SEER2 range
10–10.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A-KHP Series

A-KHP365A-1

3 published source records

19.4–23SEER2 range
10.4–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

KERRAir-source heat pump

A-KHP Series

A-KHP486A-1

3 published source records

20.4–23SEER2 range
11HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

KERRAir-source heat pump

A-KHP Series

A-KHP556A-1

3 published source records

20–22.2SEER2 range
10.5–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

KERRAir-source heat pump

A series

A-KMH06SV-1

1 published source record

26.5SEER2 range
13.6HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A series

A-KMH09SV-1

4 published source records

20.2–28.1SEER2 range
10.3–12HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

Multiple source series

A-KMH12SV-1

7 published source records

19.5–25.5SEER2 range
9.5–10.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A series

A-KMH18DV-1

4 published source records

19–22SEER2 range
9.3–9.8HSPF2 range

4 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

KERRAir-source heat pump

A series

A-KMH18SU-1

2 published source records

19.4–21.5SEER2 range
10–11.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A series

A-KMH18SU-1A

5 published source records

18–20.5SEER2 range
9.5–10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

KERRAir-source heat pump

A series

A-KMH18SV-1

6 published source records

18–21.5SEER2 range
9.5–11.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.