US EQUIPMENT REFERENCE

EMI

30 equipment models and 67 source-listed options. Brand names follow the published records; a shared manufacturer does not imply interchangeable equipment.

RefineClear

30 models · Source-backed US equipment index

A model may have several rated combinations.
EMIAir-source heat pump

ADS series

ADSZ109DA

2 published source records

18.5SEER2 range
8.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

ADS series

ADSZ130DA

1 published source record

21SEER2 range
9.1HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

ECO Series

ECOSZ109DA

1 published source record

21.6SEER2 range
9.4HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

ECO Series

ECOSZ118DA

1 published source record

20.2SEER2 range
9.1HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

ECO Series

ECOSZ124DA

1 published source record

18.5SEER2 range
9HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

ECO Series

ECOSZ130DA

1 published source record

20SEER2 range
9.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

EMX Series

EMXMZ218DA

3 published source records

20–25SEER2 range
10–10.4HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

EMX Series

EMXMZ327DA

3 published source records

19–23SEER2 range
9.5–10.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

EMX Series

EMXMZ436DA

3 published source records

19.4–23SEER2 range
10.4–10.7HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

EMX Series

EMXMZ548DA

3 published source records

20.4–23SEER2 range
11HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

EMX Series

EMXSZ106DA

1 published source record

25.5SEER2 range
14.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

EMX Series

EMXSZ109DA

1 published source record

27.4SEER2 range
12.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

EMX Series

EMXSZ112DA

1 published source record

25.4SEER2 range
10.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

EMX Series

EMXSZ118DA

1 published source record

21.4SEER2 range
11HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

EMX Series

EMXSZ124DA

1 published source record

21SEER2 range
13.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

MH series

MHMZ218DA

3 published source records

19–22SEER2 range
9.3–9.8HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

MH series

MHMZ327DA

4 published source records

20–23SEER2 range
9.5–10.6HSPF2 range

4 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

MH series

MHMZ436DA

4 published source records

19–22.2SEER2 range
10–10.3HSPF2 range

4 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

MH series

MHMZ548DA

5 published source records

20.9–21.8SEER2 range
9–9.8HSPF2 range

5 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

EMIAir-source heat pump

Multiple source series

MHSD118DACFC

2 published source records

16.1–18SEER2 range
9.3–9.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

Multiple source series

MHSD124DACFC

2 published source records

16.5–17.4SEER2 range
9.5–10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

Multiple source series

MHSD130DACFC

2 published source records

15.5–16.2SEER2 range
8.9–9.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

Multiple source series

MHSD136DACFC

3 published source records

15.2–16SEER2 range
9.5–10HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

EMIAir-source heat pump

MHAH Series

MHSD148DACFC

1 published source record

15.6SEER2 range
9.4HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.