US EQUIPMENT REFERENCE

C&H

36 equipment models and 136 source-listed options. Brand names follow the published records; a shared manufacturer does not imply interchangeable equipment.

RefineClear

36 models · Source-backed US equipment index

A model may have several rated combinations.
C&HAir-source heat pump

CH series

CH-06OLVWM-115VO

2 published source records

23SEER2 range
9.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-18MES-230VO

3 published source records

19–22.9SEER2 range
9.8–10.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-28MES-230VO

4 published source records

21–24.6SEER2 range
9.2–9.5HSPF2 range

4 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-36MES-230VO

3 published source records

20–23.9SEER2 range
9.2–9.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-48MES-230VO

2 published source records

21.95–23.4SEER2 range
8.7–9.2HSPF2 range

2 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-EL30-230VO

2 published source records

20–21SEER2 range
8.2–9.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES06-115VO

1 published source record

23SEER2 range
9.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES09-115VO

3 published source records

23SEER2 range
9.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES09-230VO

5 published source records

19.2–25.5SEER2 range
10–12.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES12-115VO

2 published source records

22.7SEER2 range
10.4HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES12-230VO

9 published source records

19–25SEER2 range
10–11HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES18-230VO

8 published source records

20–24SEER2 range
10–10.8HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-ES24-230VO

6 published source records

19–22SEER2 range
8.5–11.2HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-HPR06F9-230VO

3 published source records

23.5–26.5SEER2 range
12–13.6HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-HPR09-230VO

9 published source records

20.2–28.1SEER2 range
10.3–12HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-HPR12-230VO

8 published source records

19.5–25.5SEER2 range
9.5–10.7HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-HPR18-230VO

10 published source records

18–22SEER2 range
8.9–11.3HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-HPR19M-230VO

4 published source records

19–22SEER2 range
9.3–9.8HSPF2 range

4 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-HPR24-230VO

10 published source records

18.9–22.3SEER2 range
10.3–11.5HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.

C&HAir-source heat pump

CH series

CH-HPR28M-230VO

3 published source records

20–23SEER2 range
9.5–10.6HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-HPR36M-230VO

3 published source records

19–22.2SEER2 range
10–10.3HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-HPR48M-230VO

4 published source records

20.9–21.8SEER2 range
9–9.8HSPF2 range

4 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-HPR55M-230VO

3 published source records

18.8–22SEER2 range
9.3–9.5HSPF2 range

3 EPA outdoor-model records do not list an indoor configuration. Open the ratings to check their scope.

C&HAir-source heat pump

CH series

CH-HYP36LCUO

1 published source record

16.5SEER2 range
11HSPF2 range

Open a configuration for heating capacity at 47°F, 17°F and 5°F, COP and EER2.