YZT60B21
AFFINITY
18 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YZT60B21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 18 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 18 / 18 |
| EER2 · BTU/Wh | 11.7 | 18 / 18 |
| HSPF2 · BTU/Wh | 7.8 | 18 / 18 |
| Cooling capacity · BTU/h | 54,000–55,000 | 18 / 18 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–60,000 | 18 / 18 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–40,500 | 18 / 18 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,400–33,400 | 18 / 18 |
| COP at 5°F / −15°C | 2.08–2.28 | 18 / 18 |
| Equipment / loop type | HP - Split System | 18 / 18 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 18 / 18 |
| Compressor staging | Two-stage | 18 / 18 |
| Connected capability | No | 18 / 18 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD60JBCN1+JMVT20DC2N1AHRI reference: 209407881 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624701 → |
JHETD60JBCS2N1AHRI reference: 210279288 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624703 → |
XAFD60JBCN1+JMET18DS2N1AHRI reference: 210294831 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624704 → |
XAFD60JBCN1+JMVT20DC2N1AHRI reference: 210294870 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624705 → |
XAFD60JBCN1+ furnace: Y81E130D20SMPS1AHRI reference: 212475587 | 15.20 | 7.80 | 33400 | 2.28 | EPA 2476378 → |
XAHD60JBCN1+ furnace: Y81E080C20LMPS1AHRI reference: 212475080 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2477046 → |
XAHD60JBCN1+ furnace: Y81E130D20SMPS1AHRI reference: 212475070 | 15.20 | 7.80 | 32600 | 2.22 | EPA 2477062 → |
XAHD60JBCN1+ furnace: Y81E130D20LMPS1AHRI reference: 212475072 | 15.20 | 7.80 | 32600 | 2.22 | EPA 2478354 → |
XAHD60JBCN1+ furnace: Y81E100C20LMPS1AHRI reference: 212475326 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2478365 → |
XAFD60JBCN1+ furnace: Y81E130D20LMPS1AHRI reference: 212475589 | 15.20 | 7.80 | 33400 | 2.28 | EPA 2478774 → |
XAHD60JBCN1+ furnace: Y81E080C20SMPS1AHRI reference: 212475078 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2479146 → |
XAHD60JBCN1+ furnace: Y81E120C20LMPS1AHRI reference: 212476129 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2482387 → |
XAHD60JBCN1+ furnace: Y81E120C20SMPS1AHRI reference: 212476128 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2482389 → |
XAHD60JBCN1+ furnace: Y81E100C20SMPS1AHRI reference: 212475324 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2482741 → |
XAHD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 209407855 | 15.20 | 7.80 | 32400 | 2.08 | EPA 3624700 → |
XAHD60JBCN1+JMET18DS2N1AHRI reference: 209407882 | 15.20 | 7.80 | 32400 | 2.16 | EPA 3624702 → |
XAHD60JBCN1+ furnace: Y82E100C20LMPS1AHRI reference: 212593880 | 15.20 | 7.80 | 32600 | 2.14 | EPA 3990804 → |
XAHD60JBCN1+ furnace: Y82E120C20LMPS1AHRI reference: 212593737 | 15.20 | 7.80 | 32600 | 2.14 | EPA 3990860 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.