York / AIR-SOURCE HEAT PUMP

YH660E2S11

LX SERIES

235 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for YH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 235 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16235 / 235
EER2 · BTU/Wh11–12235 / 235
HSPF2 · BTU/Wh7.8–8.5235 / 235
Cooling capacity · BTU/h52,500–55,000235 / 235
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000235 / 235
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500235 / 235
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600235 / 235
COP at 5°F / −15°C2–2.38235 / 235
Equipment / loop typeHP - Split System235 / 235
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)235 / 235
Compressor stagingTwo-stage235 / 235
Connected capabilityNo235 / 235

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60D5CJS1+JMVT20DC2N1AHRI reference: 21701815116.008.50320002.36EPA 4014104 →
CTM60D5CJS1+ furnace: Y81E130D20SMPS1AHRI reference: 21701819216.008.10324002.34EPA 4014105 →
CTM60D5CJS1+ furnace: Y81E130D20LMPS1AHRI reference: 21701819416.008.10324002.34EPA 4014106 →
CTM60D5CHS1+JME18D2SN1AHRI reference: 21701825916.008.10316002.28EPA 4014107 →
CTM60D5CJS1+JMC20D2SN1AHRI reference: 21701826616.008.50320002.36EPA 4014108 →
CTM60D5CJS1+JME18D2SN1AHRI reference: 21701834616.008.50320002.38EPA 4014109 →
JHC60D5CH2SS1AHRI reference: 21701834816.008.10314002.30EPA 4014110 →
JHC60C5CH2SS1AHRI reference: 21701835216.008.10314002.28EPA 4014111 →
JHE60C5CH2SS1AHRI reference: 21701835416.008.10314002.28EPA 4014112 →
JHE60D5CH2SS1AHRI reference: 21701656016.008.00300002.20EPA 4014180 →
CTF60D5CJS1+ furnace: Y81E130D20SMPS1AHRI reference: 21701769016.008.50322002.36EPA 4014193 →
CTF60D5CJS1+ furnace: Y81E130D20LMPS1AHRI reference: 21701769216.008.50322002.36EPA 4014194 →
CTF60D5CJS1+JMET18DS2N1AHRI reference: 21701770816.008.50320002.36EPA 4014195 →
CTF60D5CJS1+JMVT20DC2N1AHRI reference: 21701772416.008.50320002.38EPA 4014196 →
CTF60D5CJS1+JMC20D2SN1AHRI reference: 21701773316.008.50320002.38EPA 4014197 →
CTF60D5CJS1+JME18D2SN1AHRI reference: 21701775216.008.50320002.38EPA 4014257 →
JHC60D5CJ2SS1AHRI reference: 21702192016.008.10324002.36EPA 4015272 →
JHE60D5CJ2SS1AHRI reference: 21702193516.008.50320002.38EPA 4015287 →
JSE60D5CJ2SS1AHRI reference: 21702189716.008.50320002.38EPA 4498099 →
JHE60D5CH2SS2AHRI reference: 21845672316.008.00300002.20EPA 4639378 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →