York / AIR-SOURCE HEAT PUMP

YH648E2S11

LX SERIES · source records, page 25

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS1+TXV+ furnace: TM9V100C20MP12AHRI reference: 21799378115.208.00260002.00EPA 4570449 →
CTF60C5CGS1+ furnace: YP9C100C20MP13AHRI reference: 21799377915.208.00260002.00EPA 4570450 →
CTF60C5CGS1+ furnace: TP9C100C20MP13AHRI reference: 21799377815.208.00260002.00EPA 4570451 →
CTF60C5CGS1+ furnace: TM9V100C20MP12AHRI reference: 21799377615.208.00260002.00EPA 4570452 →
CTM60C5CGS1+ furnace: YP9C100C16MP13AHRI reference: 21799377415.208.00260002.00EPA 4570453 →
CTM60C5CGS1+ furnace: TP9C100C16MP13AHRI reference: 21799377215.208.00260002.00EPA 4570454 →
CTM60C5CGS1+ furnace: TM9V100C16MP12AHRI reference: 21799377015.208.00260002.00EPA 4570455 →
CTM60C5CGS1+ furnace: YP9C080C16MP13AHRI reference: 21799376715.208.00260002.00EPA 4570456 →
CTM60C5CGS1+ furnace: TP9C080C16MP13AHRI reference: 21799376515.208.00260002.00EPA 4570457 →
CTM60C5CGS1+ furnace: TM9V080C16MP12AHRI reference: 21799376415.208.00260002.00EPA 4570458 →
CTU60C5XGS1+TXV+ furnace: YP9C080C16MP13AHRI reference: 21799376215.208.00260002.00EPA 4570459 →
CTU60C5XGS1+TXV+ furnace: TP9C080C16MP13AHRI reference: 21799376115.208.00260002.00EPA 4570460 →
CTU60C5XGS1+TXV+ furnace: TM9V080C16MP12AHRI reference: 21799375915.208.00260002.00EPA 4570461 →
CTF60C5CGS1+ furnace: YP9C080C16MP13AHRI reference: 21799375715.208.00260002.00EPA 4570462 →
CTF60C5CGS1+ furnace: TP9C080C16MP13AHRI reference: 21799375615.208.00260002.00EPA 4570463 →
CTF60C5CGS1+ furnace: TM9V080C16MP12AHRI reference: 21799375415.208.00260002.00EPA 4570464 →
CTM60D5CGS1+ furnace: Y91E120D20SMPS1AHRI reference: 21702192615.208.10276002.24EPA 4570512 →
CTM60C5CGS1+ furnace: Y91E100C16SMPS1AHRI reference: 21702190315.208.10272002.24EPA 4570513 →
CTU60C5XGS1+TXV+ furnace: Y92E080C16SMPS1AHRI reference: 21701942215.208.10278002.20EPA 4570544 →
CTF60C5CGS1+ furnace: Y92E080C16SMPS1AHRI reference: 21701942015.208.10278002.20EPA 4570545 →