York / AIR-SOURCE HEAT PUMP

YH648E2S11

LX SERIES · source records, page 20

554 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16554 / 554
EER2 · BTU/Wh11.7–12554 / 554
HSPF2 · BTU/Wh7.8–8.1554 / 554
Cooling capacity · BTU/h45,000–49,000554 / 554
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000554 / 554
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000554 / 554
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800554 / 554
COP at 5°F / −15°C2–2.4554 / 554
Equipment / loop typeHP - Split System554 / 554
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)554 / 554
Compressor stagingTwo-stage554 / 554
Connected capabilityNo554 / 554

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: Y81E080C16SMPS1AHRI reference: 21850875116.008.10270002.26EPA 4640327 →
CTF60C5CGS2+ furnace: Y81E080C16LMPS1AHRI reference: 21850874816.008.10270002.26EPA 4640328 →
CTF60C5CGS2+ furnace: Y81E080C16SMPS1AHRI reference: 21850874616.008.10270002.26EPA 4640329 →
CTU60C5XGS2+TXV+ furnace: Y82E100C20LMPS1AHRI reference: 21850874216.008.10276002.26EPA 4640330 →
CTF60C5CGS2+ furnace: Y82E100C20LMPS1AHRI reference: 21850874016.008.10276002.26EPA 4640331 →
CTU60C5XGS2+TXV+ furnace: Y82E100C16LMPS1AHRI reference: 21850873716.008.10274002.24EPA 4640332 →
CTF60C5CGS2+ furnace: Y82E100C16LMPS1AHRI reference: 21850873416.008.10274002.24EPA 4640333 →
CTU60C5XGS2+TXV+ furnace: Y82E080C16LMPS1AHRI reference: 21850873216.008.10270002.26EPA 4640334 →
CTF60C5CGS2+ furnace: Y82E080C16LMPS1AHRI reference: 21850872916.008.10270002.26EPA 4640335 →
CTU60C5XGS2+TXV+ furnace: Y92E100C20SMPS1AHRI reference: 21850872616.008.10274002.22EPA 4640336 →
CTF60C5CGS2+ furnace: Y92E100C20SMPS1AHRI reference: 21850872316.008.10274002.22EPA 4640337 →
CTU60C5XGS2+TXV+ furnace: Y91E100C20SMPS1AHRI reference: 21850872116.008.10274002.22EPA 4640338 →
CTF60C5CGS2+ furnace: Y91E100C20SMPS1AHRI reference: 21850871816.008.10274002.22EPA 4640339 →
CTU60C5XGS2+TXV+ furnace: Y81E080C20LMPS1AHRI reference: 21850871516.008.10276002.26EPA 4640340 →
CTU60C5XGS2+TXV+ furnace: Y81E080C20SMPS1AHRI reference: 21850871216.008.10276002.26EPA 4640341 →
CTF60C5CGS2+ furnace: Y81E080C20LMPS1AHRI reference: 21850871016.008.10276002.26EPA 4640342 →
CTF60C5CGS2+ furnace: Y81E080C20SMPS1AHRI reference: 21850870716.008.10276002.26EPA 4640343 →
CTU60C5XGS2+TXV+ furnace: Y81E100C16LMPS1AHRI reference: 21850869916.008.10276002.26EPA 4640346 →
CTU60C5XGS2+TXV+ furnace: Y81E100C16SMPS1AHRI reference: 21850869716.008.10276002.26EPA 4640347 →
CTF60C5CGS2+ furnace: Y81E100C16LMPS1AHRI reference: 21850869416.008.10276002.26EPA 4640348 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →