YH648E2S11
LX SERIES · source records, page 11
554 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 554 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 554 / 554 |
| EER2 · BTU/Wh | 11.7–12 | 554 / 554 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 554 / 554 |
| Cooling capacity · BTU/h | 45,000–49,000 | 554 / 554 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 554 / 554 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 554 / 554 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 554 / 554 |
| COP at 5°F / −15°C | 2–2.4 | 554 / 554 |
| Equipment / loop type | HP - Split System | 554 / 554 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 554 / 554 |
| Compressor staging | Two-stage | 554 / 554 |
| Connected capability | No | 554 / 554 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS1+TXV+ furnace: Y82V080C16SMPC1AHRI reference: 217445104 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4045159 → |
CTF60C5CGS1+ furnace: Y82V080C16SMPC1AHRI reference: 217445103 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4045160 → |
CTU60C5XGS1+TXV+ furnace: Y82V120C20SMPC1AHRI reference: 217445106 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4045161 → |
CTF60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 217445105 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4045162 → |
CTM60C5CGS1+ furnace: Y82V080C16SMPC1AHRI reference: 217445102 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4045163 → |
CTM60C5CHS1+ furnace: Y82V080C16SMPC1AHRI reference: 217445107 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4045164 → |
CTF60C5CHS1+ furnace: Y82V100C16SMPC1AHRI reference: 217445108 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4045165 → |
CTM60C5CHS1+ furnace: Y82V100C16SMPC1AHRI reference: 217445109 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4045166 → |
CTM60C5CHS1+ furnace: Y82V100C20SMPC1AHRI reference: 217445110 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4045167 → |
CTM60C5CHS1+ furnace: Y82V120C20SMPC1AHRI reference: 217445111 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4045168 → |
CTF60C5CHS1+ furnace: Y82V120C20SMPC1AHRI reference: 217445113 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4045169 → |
CTF60C5CHS1+ furnace: Y82V100C20SMPC1AHRI reference: 217445112 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4045170 → |
CTF60C5CHS1+ furnace: Y82V080C16SMPC1AHRI reference: 217445114 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4045171 → |
CTU60C5XGS1+TXV+ furnace: Y82V100C16SMPC1AHRI reference: 217445097 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4045188 → |
CTM60C5CGS1+ furnace: Y82V100C20SMPC1AHRI reference: 217445095 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4045190 → |
CTF60C5CGS1+ furnace: Y82V100C16SMPC1AHRI reference: 217445096 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4045191 → |
JSC48D5CG2SS1AHRI reference: 217598320 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497245 → |
JSC48C5CG2SS1AHRI reference: 217598336 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497259 → |
CTF60C5CGS1+ furnace: Y82V100C20SMPC1AHRI reference: 217445099 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4497700 → |
JSE48D5CG2SS1AHRI reference: 217598321 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497870 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →