York / AIR-SOURCE HEAT PUMP

YH636E2S11

LX SERIES · source records, page 20

496 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for YH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17496 / 496
EER2 · BTU/Wh11–12496 / 496
HSPF2 · BTU/Wh8–8.5496 / 496
Cooling capacity · BTU/h32,800–36,000496 / 496
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200496 / 496
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800496 / 496
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800496 / 496
COP at 5°F / −15°C2–2.5496 / 496
Equipment / loop typeHP - Split System496 / 496
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)496 / 496
Compressor stagingTwo-stage496 / 496
Connected capabilityNo496 / 496

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: YP9C080C16MP13AHRI reference: 21799366315.208.10180002.00EPA 4514709 →
CTM36C5CDS1+ furnace: TM9V080C16MP12AHRI reference: 21799366115.208.10180002.00EPA 4514710 →
CTF36B5CDS1+ furnace: TM9V080B12MP12AHRI reference: 21799366415.208.10180002.00EPA 4514711 →
CTF36B5CDS1+ furnace: YP9C080B12MP13AHRI reference: 21799366615.208.10180002.00EPA 4514712 →
CTF36B5CDS1+ furnace: TP9C080B12MP13AHRI reference: 21799366515.208.10180002.00EPA 4514713 →
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21799366815.208.10180002.00EPA 4514714 →
CTU36B5XDS1+TXV+ furnace: YP9C080B12MP13AHRI reference: 21799367015.208.10180002.00EPA 4514716 →
CTU36B5XDS1+TXV+ furnace: TM9V080B12MP12AHRI reference: 21799366715.208.10180002.00EPA 4514717 →
CTF36C5CDS1+ furnace: TM9V100C20MP12AHRI reference: 21799367115.208.10180002.00EPA 4514718 →
CTF36C5CDS1+ furnace: TP9C100C20MP13AHRI reference: 21799367315.208.10180002.00EPA 4514721 →
CTM36C5CDS1+ furnace: TM9V100C20MP12AHRI reference: 21799367715.208.10180002.00EPA 4514722 →
CTM36C5CDS1+ furnace: TP9C100C20MP13AHRI reference: 21799367915.208.10180002.00EPA 4514725 →
CTM36C5CDS1+ furnace: YP9C100C20MP13AHRI reference: 21799368015.208.10180002.00EPA 4514726 →
CTF36B5CDS1+ furnace: TP9C060B12MP13AHRI reference: 21799368415.208.10180002.00EPA 4514728 →
CTF36B5CDS1+ furnace: TM9V060B12MP12AHRI reference: 21799368215.208.10180002.00EPA 4514729 →
CTF36C5CDS1+ furnace: YP9C100C20MP13AHRI reference: 21799367515.208.10180002.00EPA 4514731 →
CTF36B5CDS1+ furnace: YP9C060B12MP13AHRI reference: 21799368615.208.10180002.00EPA 4514733 →
CTU36B5XDS1+TXV+ furnace: TP9C060B12MP13AHRI reference: 21799368915.208.10180002.00EPA 4514735 →
CTU36B5XDS1+TXV+ furnace: TM9V060B12MP12AHRI reference: 21799368715.208.10180002.00EPA 4514737 →
CTU36B5XDS1+TXV+ furnace: YP9C060B12MP13AHRI reference: 21799369215.208.10180002.00EPA 4514739 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.