YH636E2S11
LX SERIES
496 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 496 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 496 / 496 |
| EER2 · BTU/Wh | 11–12 | 496 / 496 |
| HSPF2 · BTU/Wh | 8–8.5 | 496 / 496 |
| Cooling capacity · BTU/h | 32,800–36,000 | 496 / 496 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 496 / 496 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,000–23,800 | 496 / 496 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,600–19,800 | 496 / 496 |
| COP at 5°F / −15°C | 2–2.5 | 496 / 496 |
| Equipment / loop type | HP - Split System | 496 / 496 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 496 / 496 |
| Compressor staging | Two-stage | 496 / 496 |
| Connected capability | No | 496 / 496 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS1+JMET12CS2N1AHRI reference: 217017113 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4012799 → |
CTU48C5XFS1+JMET12CS2N1+TXVAHRI reference: 217017115 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4012800 → |
CTF48C5CFS1+JMC16C2SN1AHRI reference: 217017117 | 17.00 | 8.50 | 19300 | 2.46 | EPA 4012802 → |
CTU48C5XFS1+JMC16C2SN1+TXVAHRI reference: 217017119 | 17.00 | 8.50 | 19300 | 2.46 | EPA 4012804 → |
CTF48C5CFS1+ furnace: Y82E080C16LMPS1AHRI reference: 217017121 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4012806 → |
CTU48C5XFS1+TXV+ furnace: Y82E080C16LMPS1AHRI reference: 217017123 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4012808 → |
CTF48C5CFS1+ furnace: Y82E120C20LMPS1AHRI reference: 217017125 | 17.00 | 8.10 | 19400 | 2.44 | EPA 4012810 → |
CTU48C5XFS1+TXV+ furnace: Y82E120C20LMPS1AHRI reference: 217017127 | 17.00 | 8.10 | 19400 | 2.44 | EPA 4012812 → |
CTF48C5CFS1+JME16C2SN1AHRI reference: 217017217 | 17.00 | 8.10 | 18900 | 2.46 | EPA 4012836 → |
CTU48C5XFS1+JME16C2SN1+TXVAHRI reference: 217017219 | 17.00 | 8.10 | 18900 | 2.46 | EPA 4012838 → |
CTF48C5CFS1+ furnace: Y81E120C16SMPS1AHRI reference: 217017221 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4012841 → |
CTF48C5CFS1+ furnace: Y81E120C16LMPS1AHRI reference: 217017223 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4012843 → |
CTU48C5XFS1+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 217017225 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4012845 → |
CTU48C5XFS1+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 217017227 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4012847 → |
CTF48D5CFS1+JME18D2SN1AHRI reference: 217017229 | 17.00 | 8.50 | 19000 | 2.48 | EPA 4012848 → |
CTF48C5CFS1+ furnace: Y82E100C16LMPS1AHRI reference: 217017231 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4012850 → |
CTU48C5XFS1+TXV+ furnace: Y82E100C16LMPS1AHRI reference: 217017232 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4012851 → |
CTF48C5CFS1+JMC17C2SN1AHRI reference: 217017255 | 17.00 | 8.50 | 19100 | 2.46 | EPA 4012866 → |
CTU48C5XFS1+JMC17C2SN1+TXVAHRI reference: 217017257 | 17.00 | 8.50 | 19100 | 2.46 | EPA 4012868 → |
CTF48C5CFS1+JMVT16CC2N1AHRI reference: 217017259 | 17.00 | 8.50 | 19300 | 2.46 | EPA 4012870 → |