YH630E2S11
LX SERIES · source records, page 6
166 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 166 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 166 / 166 |
| EER2 · BTU/Wh | 11–13 | 166 / 166 |
| HSPF2 · BTU/Wh | 8–8.1 | 166 / 166 |
| Cooling capacity · BTU/h | 28,400–31,000 | 166 / 166 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 28,800–30,000 | 166 / 166 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 18,800–20,200 | 166 / 166 |
| Heating capacity at 5°F / −15°C · BTU/h | 15,000–16,400 | 166 / 166 |
| COP at 5°F / −15°C | 2–2.4 | 166 / 166 |
| Equipment / loop type | HP - Split System | 166 / 166 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 166 / 166 |
| Compressor staging | Two-stage | 166 / 166 |
| Connected capability | No | 166 / 166 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30B5AZS2+ furnace: Y92V080B12SMPC1AHRI reference: 218687067 | 16.00 | 8.10 | 15400 | 2.00 | EPA 4673386 → |
CTF30B5AZS2+ furnace: Y92V060B12SMPC1AHRI reference: 218687063 | 16.00 | 8.10 | 15400 | 2.00 | EPA 4673390 → |
CTF30B5AZS2+ furnace: TM9Y080B12MP11AHRI reference: 218687059 | 16.00 | 8.10 | 16200 | 2.00 | EPA 4673394 → |
CTM30B5AZS2+ furnace: Y81E080B12LMPS1AHRI reference: 218687058 | 16.00 | 8.10 | 15600 | 2.00 | EPA 4673395 → |
CTM30B5AZS2+ furnace: Y81E080B12SMPS1AHRI reference: 218687057 | 16.00 | 8.10 | 15600 | 2.00 | EPA 4673396 → |
CTF30B5AZS2+ furnace: Y82E080B12LMPS1AHRI reference: 218687048 | 16.00 | 8.10 | 15200 | 2.00 | EPA 4673405 → |
CTF30B5AZS2+ furnace: Y81E100B12LMPS1AHRI reference: 218687047 | 16.00 | 8.10 | 15400 | 2.00 | EPA 4673406 → |
CTF30B5AZS2+ furnace: Y81E100B12SMPS1AHRI reference: 218687046 | 16.00 | 8.10 | 15400 | 2.00 | EPA 4673407 → |
CTF30B5AZS2+ furnace: Y82V080B12SMPC1AHRI reference: 218687042 | 16.00 | 8.10 | 15400 | 2.00 | EPA 4673411 → |
JHC30B5AZ2SS1AHRI reference: 218687040 | 16.00 | 8.10 | 15600 | 2.00 | EPA 4673413 → |
CTM30B5AZS2+ furnace: Y82V080B12SMPC1AHRI reference: 218687038 | 16.00 | 8.10 | 15400 | 2.00 | EPA 4673415 → |
CTM30B5AZS2+ furnace: Y82E080B12LMPS1AHRI reference: 218687032 | 16.00 | 8.10 | 15200 | 2.00 | EPA 4673421 → |
JHE30B5AZ2SS2AHRI reference: 218687029 | 16.00 | 8.10 | 15600 | 2.00 | EPA 4673422 → |
CTF36B5ADS1+ furnace: Y92V080B12SMPC1AHRI reference: 218702949 | 16.00 | 8.10 | 15600 | 2.30 | EPA 4691640 → |
CTM36B5ADS1+ furnace: Y92V060B12SMPC1AHRI reference: 218702947 | 16.00 | 8.00 | 15600 | 2.28 | EPA 4691641 → |
CTM36B5ADS1+ furnace: Y92V080B12SMPC1AHRI reference: 218702940 | 16.00 | 8.10 | 15600 | 2.30 | EPA 4691642 → |
CTF36C5ADS1+ furnace: Y92V080C16SMPC1AHRI reference: 218702963 | 16.00 | 8.10 | 15400 | 2.34 | EPA 4691643 → |
CTM36C5ADS1+ furnace: Y92V080C16SMPC1AHRI reference: 218702960 | 16.00 | 8.10 | 15200 | 2.34 | EPA 4691644 → |
CTU36B5XDS1+TXV+ furnace: Y92V060B12SMPC1AHRI reference: 218702958 | 16.00 | 8.10 | 15600 | 2.30 | EPA 4691645 → |
CTF36B5ADS1+ furnace: Y92V060B12SMPC1AHRI reference: 218702955 | 16.00 | 8.10 | 15600 | 2.30 | EPA 4691646 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →