York / AIR-SOURCE HEAT PUMP

YH630E2S11

LX SERIES · source records, page 3

166 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for YH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 166 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17166 / 166
EER2 · BTU/Wh11–13166 / 166
HSPF2 · BTU/Wh8–8.1166 / 166
Cooling capacity · BTU/h28,400–31,000166 / 166
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000166 / 166
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200166 / 166
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400166 / 166
COP at 5°F / −15°C2–2.4166 / 166
Equipment / loop typeHP - Split System166 / 166
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)166 / 166
Compressor stagingTwo-stage166 / 166
Connected capabilityNo166 / 166

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU36B5XDS1+TXV+ furnace: Y81E100B12LMPS1AHRI reference: 21841699516.008.10152002.36EPA 4608272 →
CTU36B5XDS1+TXV+ furnace: Y81E100B12SMPS1AHRI reference: 21841699416.008.10152002.36EPA 4608273 →
CTF36B5ADS1+ furnace: Y81E100B12LMPS1AHRI reference: 21841699316.008.10152002.36EPA 4608274 →
CTF36B5ADS1+ furnace: Y81E100B12SMPS1AHRI reference: 21841699216.008.10152002.36EPA 4608275 →
CTM36C5ADS1+ furnace: YP9C080C16MP13AHRI reference: 21841699116.008.10156002.30EPA 4608276 →
CTM36C5ADS1+ furnace: TP9C080C16MP13AHRI reference: 21841699016.008.10156002.30EPA 4608277 →
CTM36C5ADS1+ furnace: TM9V080C16MP12AHRI reference: 21841698916.008.10156002.30EPA 4608278 →
CTM36B5ADS1+ furnace: YP9C080B12MP13AHRI reference: 21841698816.008.00156002.28EPA 4608279 →
CTM36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21841698716.008.00156002.28EPA 4608280 →
CTM36B5ADS1+ furnace: TM9V080B12MP12AHRI reference: 21841698616.008.00156002.28EPA 4608281 →
CTU36B5XDS1+TXV+ furnace: TM9E080B12MP12AHRI reference: 21841698516.008.10156002.28EPA 4608282 →
CTF36B5ADS1+ furnace: TM9E080B12MP12AHRI reference: 21841698416.008.10156002.28EPA 4608283 →
CTF36C5ADS1+ furnace: Y82V080C16SMPC1AHRI reference: 21841698316.008.10150002.40EPA 4608284 →
CTU36B5XDS1+TXV+ furnace: Y91E080B12SMPS1AHRI reference: 21841697616.008.10158002.26EPA 4608291 →
CTF36B5ADS1+ furnace: Y91E080B12SMPS1AHRI reference: 21841697516.008.10158002.26EPA 4608292 →
CTM36C5ADS1+ furnace: Y82V080C16SMPC1AHRI reference: 21841697216.008.10150002.40EPA 4608295 →
CTM36C5ADS1+ furnace: Y91E080C16SMPS1AHRI reference: 21841697116.008.10154002.32EPA 4608296 →
CTM36C5ADS1+ furnace: Y92E080C16SMPS1AHRI reference: 21841697016.008.10154002.32EPA 4608297 →
CTU36B5XDS1+TXV+ furnace: YP9C080B12MP13AHRI reference: 21841696916.008.10156002.28EPA 4608298 →
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21841696816.008.10156002.28EPA 4608299 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →