YH624E2S11
LX SERIES · source records, page 3
157 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 157 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 157 / 157 |
| EER2 · BTU/Wh | 11.7–12 | 157 / 157 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 157 / 157 |
| Cooling capacity · BTU/h | 22,800–24,200 | 157 / 157 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–24,000 | 157 / 157 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 157 / 157 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 157 / 157 |
| COP at 5°F / −15°C | 2–2.3 | 157 / 157 |
| Equipment / loop type | HP - Split System | 157 / 157 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 157 / 157 |
| Compressor staging | Two-stage | 157 / 157 |
| Connected capability | No | 157 / 157 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30C5ACS1+JME12C2SN1AHRI reference: 217016791 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4570685 → |
CTF30C5ACS1+JMET12CS2N1AHRI reference: 217016790 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4570686 → |
CTF30C5ACS1+ furnace: Y82E120C20LMPS1AHRI reference: 217016789 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4570687 → |
CTF30C5ACS1+JME16C2SN1AHRI reference: 217016788 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4570688 → |
CTF30C5ACS1+JMET16CS2N1AHRI reference: 217016777 | 16.00 | 7.80 | 12300 | 2.16 | EPA 4570689 → |
CTF30C5ACS1+ furnace: Y92E100C16SMPS1AHRI reference: 217016776 | 16.00 | 7.80 | 12400 | 2.10 | EPA 4570690 → |
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 217016769 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4570691 → |
CTF30B5ACS1+JMC12B2SN1AHRI reference: 217016768 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4570692 → |
CTU30B5XCS1+JMVT12BC2N1+TXVAHRI reference: 217016767 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4570693 → |
CTF30B5ACS1+JMVT12BC2N1AHRI reference: 217016766 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4570694 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 217016760 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4570695 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 217016759 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4570696 → |
JHE30B5AD2SS2AHRI reference: 218456720 | 16.00 | 8.10 | 12100 | 2.26 | EPA 4639381 → |
JHE24B5AC2SS2AHRI reference: 218456719 | 16.00 | 8.00 | 12000 | 2.12 | EPA 4639382 → |
CTM36B5ADS2+ furnace: Y81E100B12LMPS1AHRI reference: 218508189 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4640521 → |
CTM36B5ADS2+ furnace: Y81E100B12SMPS1AHRI reference: 218508186 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4640522 → |
CTM36B5ADS2+ furnace: Y82E080B12LMPS1AHRI reference: 218508184 | 16.00 | 8.10 | 12400 | 2.26 | EPA 4640523 → |
CTM30B5ACS2+ furnace: Y81E100B12LMPS1AHRI reference: 218508167 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4640526 → |
CTM30B5ACS2+ furnace: Y81E100B12SMPS1AHRI reference: 218508164 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4640527 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218508156 | 16.00 | 7.80 | 12200 | 2.12 | EPA 4640528 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →