York / AIR-SOURCE HEAT PUMP

YH618E2S11

LX SERIES · source records, page 14

288 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for YH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 288 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16288 / 288
EER2 · BTU/Wh12–12.5288 / 288
HSPF2 · BTU/Wh7.8–8288 / 288
Cooling capacity · BTU/h17,000–18,300288 / 288
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000288 / 288
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300288 / 288
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100288 / 288
COP at 5°F / −15°C2.26–2.34288 / 288
Equipment / loop typeHP - Split System288 / 288
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)288 / 288
Compressor stagingSingle stage288 / 288
Connected capabilityNo288 / 288

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU24A5XBS2+TXV+ furnace: YPLC060A12MP13AHRI reference: 21850938315.207.8089002.26EPA 4641495 →
CTU24A5XBS2+TXV+ furnace: TPLC060A12MP13AHRI reference: 21850938115.207.8089002.26EPA 4641496 →
CTU24A5XBS2+TXV+ furnace: TMLV060A12MP12AHRI reference: 21850937815.207.8089002.26EPA 4641497 →
CTU24A5XBS2+TXV+ furnace: TM8V060A12MP12AHRI reference: 21850937615.207.8089002.26EPA 4641498 →
CTF24A5ABS2+ furnace: YPLC060A12MP13AHRI reference: 21850937315.207.8089002.26EPA 4641499 →
CTF24A5ABS2+ furnace: TPLC060A12MP13AHRI reference: 21850937115.207.8089002.26EPA 4641500 →
CTF24A5ABS2+ furnace: TMLV060A12MP12AHRI reference: 21850936915.207.8089002.26EPA 4641501 →
CTF24A5ABS2+ furnace: TM8V060A12MP12AHRI reference: 21850936615.207.8089002.26EPA 4641502 →
CTU24A5XBS2+TXV+ furnace: Y81E040A12LMPS1AHRI reference: 21850936015.207.8088002.28EPA 4641503 →
CTU24A5XBS2+TXV+ furnace: Y81E040A12SMPS1AHRI reference: 21850935815.207.8088002.28EPA 4641504 →
CTF24A5ABS2+ furnace: Y81E040A12LMPS1AHRI reference: 21850935515.207.8088002.28EPA 4641505 →
CTF24A5ABS2+ furnace: Y81E040A12SMPS1AHRI reference: 21850935315.207.8088002.28EPA 4641506 →
CTU24A5XBS2+TXV+ furnace: TMLE060A12MP11AHRI reference: 21850935115.207.8090002.26EPA 4641507 →
CTU24A5XBS2+TXV+ furnace: TM8E060A12MP11AHRI reference: 21850934815.207.8090002.26EPA 4641508 →
CTF24A5ABS2+ furnace: TMLE060A12MP11AHRI reference: 21850934715.207.8090002.26EPA 4641509 →
CTF24A5ABS2+ furnace: TM8E060A12MP11AHRI reference: 21850934415.207.8090002.26EPA 4641510 →
CTU24A5XBS2+TXV+ furnace: Y81E060A12LMPS1AHRI reference: 21850933115.207.8088002.28EPA 4641511 →
CTU24A5XBS2+TXV+ furnace: Y81E060A12SMPS1AHRI reference: 21850932815.207.8088002.28EPA 4641512 →
CTF24A5ABS2+ furnace: Y81E060A12LMPS1AHRI reference: 21850932615.207.8088002.28EPA 4641513 →
CTF24A5ABS2+ furnace: Y81E060A12SMPS1AHRI reference: 21850932415.207.8088002.28EPA 4641514 →