York / AIR-SOURCE HEAT PUMP

YH548E2S11

LX SERIES · source records, page 19

381 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,500–48,000BTU/h

Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16381 / 381
EER2 · BTU/Wh11–12381 / 381
HSPF2 · BTU/Wh7.8–8.1381 / 381
Cooling capacity · BTU/h45,500–48,000381 / 381
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000381 / 381
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400381 / 381
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200381 / 381
COP at 5°F / −15°C2.1–2.42381 / 381
Equipment / loop typeHP - Split System381 / 381
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)381 / 381
Compressor stagingTwo-stage381 / 381
Connected capabilityNo381 / 381

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+JMC16C2SN1+TXVAHRI reference: 21850025215.207.80250002.26EPA 4640159 →
CTF60C5CGS2+JMC16C2SN1AHRI reference: 21850025115.207.80250002.26EPA 4640160 →
CTU60C5XGS2+JMVT16CC2N1+TXVAHRI reference: 21850025015.207.80250002.26EPA 4640161 →
CTF60C5CGS2+JMVT16CC2N1AHRI reference: 21850024915.207.80250002.26EPA 4640162 →
CTU60C5XGS2+JMC17C2SN1+TXVAHRI reference: 21850022815.207.80250002.26EPA 4640163 →
CTF60C5CGS2+JMC17C2SN1AHRI reference: 21850022715.207.80250002.26EPA 4640164 →
CTU60C5XGS2+JMVT17CC2N1+TXVAHRI reference: 21850022615.207.80250002.26EPA 4640165 →
CTF60C5CGS2+JMVT17CC2N1AHRI reference: 21850022515.207.80250002.26EPA 4640166 →
CTU60C5XGS2+TXV+ furnace: Y82E120C20LMPS1AHRI reference: 21850022015.207.80260002.26EPA 4640167 →
CTF60C5CGS2+ furnace: Y82E120C20LMPS1AHRI reference: 21850021915.207.80260002.26EPA 4640168 →
CTM60C5CHS2+JME12C2SN2AHRI reference: 21863686715.208.00258002.40EPA 4663680 →
CTF60C5CHS2+JME12C2SN2AHRI reference: 21863686315.207.80258002.40EPA 4663681 →
CTM60D5CGS2+JME18D2SN2AHRI reference: 21863662215.207.80254002.28EPA 4663788 →
CTF60D5CGS2+JME18D2SN2AHRI reference: 21863662015.207.80250002.26EPA 4663790 →
CTF60C5CHS2+JME16C2SN2AHRI reference: 21863661915.208.10262002.38EPA 4663791 →
CTM60C5CGS2+JME16C2SN2AHRI reference: 21863661815.207.80256002.28EPA 4663792 →
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 21863661715.207.80252002.24EPA 4663793 →
CTF60C5CGS2+JME16C2SN2AHRI reference: 21863661615.207.80252002.24EPA 4663794 →
CTM60C5CHS2+JME16C2SN2AHRI reference: 21863661515.208.10264002.40EPA 4663795 →
CTF60D5CHS2+JME18D2SN2AHRI reference: 21863661315.208.10260002.40EPA 4663797 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →