YH548E2S11
LX SERIES · source records, page 11
381 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 381 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 381 / 381 |
| EER2 · BTU/Wh | 11–12 | 381 / 381 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 381 / 381 |
| Cooling capacity · BTU/h | 45,500–48,000 | 381 / 381 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 381 / 381 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 381 / 381 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 381 / 381 |
| COP at 5°F / −15°C | 2.1–2.42 | 381 / 381 |
| Equipment / loop type | HP - Split System | 381 / 381 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 381 / 381 |
| Compressor staging | Two-stage | 381 / 381 |
| Connected capability | No | 381 / 381 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS1+ furnace: Y91E100C16SMPS1AHRI reference: 214605035 | 15.20 | 7.80 | 26600 | 2.32 | EPA 4570771 → |
CTM60C5CGS1+ furnace: Y81E080C20SMPS1AHRI reference: 214426059 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4570818 → |
CTM60C5CGS1+ furnace: Y81E100C20SMPS1AHRI reference: 214426005 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570819 → |
CTM60C5CGS1+JMET16CS2N1AHRI reference: 214426001 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570820 → |
CTM60C5CGS1+JMC16C2SN1AHRI reference: 214425883 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570823 → |
CTF60C5CGS1+JMET16CS2N1AHRI reference: 214425792 | 15.20 | 7.80 | 25200 | 2.24 | EPA 4570824 → |
CTM60C5CHS1+ furnace: YP9C100C20MP13AHRI reference: 214425770 | 15.20 | 7.80 | 27000 | 2.30 | EPA 4570827 → |
CTM60C5CHS1+ furnace: TP9C100C20MP13AHRI reference: 214425768 | 15.20 | 7.80 | 27000 | 2.30 | EPA 4570828 → |
CTM60C5CHS1+ furnace: TM9V100C20MP12AHRI reference: 214425766 | 15.20 | 7.80 | 27000 | 2.30 | EPA 4570829 → |
CTM60C5CGS1+JMVT16CC2N1AHRI reference: 214425668 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4570830 → |
CTF60C5CGS1+JMC17C2SN1AHRI reference: 214425569 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4570831 → |
CTF60D5CHS1+ furnace: YP9C120D20MP13AHRI reference: 214425553 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4570835 → |
CTF60D5CHS1+ furnace: TP9C120D20MP13AHRI reference: 214425551 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4570836 → |
CTF60D5CHS1+ furnace: TM9V120D20MP12AHRI reference: 214425549 | 15.20 | 7.80 | 26800 | 2.34 | EPA 4570837 → |
CTM60C5CHS1+ furnace: TM8V080C16MP12AHRI reference: 214425413 | 15.20 | 7.80 | 26400 | 2.34 | EPA 4570845 → |
CTM60C5CHS1+ furnace: TM8V100C16MP12AHRI reference: 214425411 | 15.20 | 7.80 | 26400 | 2.34 | EPA 4570846 → |
CTM60C5CGS1+ furnace: Y81E100C16SMPS1AHRI reference: 214425407 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4570847 → |
CTM60C5CHS1+ furnace: TL9E080C16UH11AHRI reference: 214425296 | 15.20 | 7.80 | 26800 | 2.30 | EPA 4570849 → |
CTF60C5CGS1+ furnace: Y81E120C16SMPS1AHRI reference: 214425218 | 15.20 | 7.80 | 25800 | 2.20 | EPA 4570850 → |
CTM60C5CGS1+ furnace: Y81E120C16SMPS1AHRI reference: 214425216 | 15.20 | 7.80 | 25800 | 2.26 | EPA 4570851 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →