York / AIR-SOURCE HEAT PUMP

YH524E2S11

LX SERIES · source records, page 3

55 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,000–24,000BTU/h

Each efficiency range summarizes published EPA records for YH524E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 55 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1655 / 55
EER2 · BTU/Wh11.7–1255 / 55
HSPF2 · BTU/Wh7.8–8.155 / 55
Cooling capacity · BTU/h23,000–24,00055 / 55
Heating capacity at 47°F / 8.3°C · BTU/h22,200–23,60055 / 55
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,40055 / 55
Heating capacity at 5°F / −15°C · BTU/h11,200–12,70055 / 55
COP at 5°F / −15°C2–2.2855 / 55
Equipment / loop typeHP - Split System55 / 55
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)55 / 55
Compressor stagingTwo-stage55 / 55
Connected capabilityNo55 / 55

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM30B5ACS2+ furnace: Y91E080B12SMPS1AHRI reference: 21850584315.208.00123002.22EPA 4640903
CTM30B5ACS2+ furnace: Y82E080B12LMPS1AHRI reference: 21850584015.208.10124002.26EPA 4640904
CTM30B5ACS2+ furnace: Y92E060B12SMPS1AHRI reference: 21850583615.208.00127002.22EPA 4640905
CTM30B5ACS2+JMC12B2SN1AHRI reference: 21850583315.208.10123002.28EPA 4640906
CTM30B5ACS2+JMVT12BC2N1AHRI reference: 21850583015.208.10123002.28EPA 4640907
CTU30B5XCS2+TXV+ furnace: Y92E080B12SMPS1AHRI reference: 21850582515.208.10125002.24EPA 4640909
CTF30B5ACS2+ furnace: Y92E080B12SMPS1AHRI reference: 21850582215.208.10125002.24EPA 4640910
CTU30B5XCS2+TXV+ furnace: Y92E060B12SMPS1AHRI reference: 21850582015.208.10126002.22EPA 4640911
CTF30B5ACS2+ furnace: Y92E060B12SMPS1AHRI reference: 21850581715.208.10126002.22EPA 4640912
CTU30B5XCS2+JMVT12BC2N1+TXVAHRI reference: 21850581515.207.80123002.18EPA 4640913
CTF30B5ACS2+JMVT12BC2N1AHRI reference: 21850581315.207.80123002.18EPA 4640914
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 21850576815.207.80117002.06EPA 4640915
CTF30B5ACS2+JMC12B2SN1AHRI reference: 21850576515.207.80117002.06EPA 4640916
CTM30B5ACS2+JME08B2SN2AHRI reference: 21863675415.208.00121002.24EPA 4663740
CTM30B5ACS2+JME12B2SN2AHRI reference: 21863675115.208.00122002.26EPA 4663741

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →