YH518E2S11
LX SERIES · source records, page 11
249 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for YH518E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 249 / 249 |
| EER2 · BTU/Wh | 12–12.5 | 249 / 249 |
| HSPF2 · BTU/Wh | 7.8 | 249 / 249 |
| Cooling capacity · BTU/h | 17,000–18,600 | 249 / 249 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 249 / 249 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 249 / 249 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 249 / 249 |
| COP at 5°F / −15°C | 2.26–2.34 | 249 / 249 |
| Equipment / loop type | HP - Split System | 249 / 249 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 249 / 249 |
| Compressor staging | Single stage | 249 / 249 |
| Connected capability | No | 249 / 249 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU30B5XCS2+TXV+ furnace: Y92E080B12SMPS1AHRI reference: 218506783 | 15.20 | 7.80 | 9100 | 2.30 | EPA 4640839 → |
CTF30B5ACS2+ furnace: Y92E080B12SMPS1AHRI reference: 218506780 | 15.20 | 7.80 | 9100 | 2.30 | EPA 4640840 → |
CTU30B5XCS2+TXV+ furnace: TL9E060B12UH11AHRI reference: 218506778 | 15.20 | 7.80 | 9100 | 2.26 | EPA 4640841 → |
CTF30B5ACS2+ furnace: TL9E060B12UH11AHRI reference: 218506775 | 15.20 | 7.80 | 9100 | 2.26 | EPA 4640842 → |
CTU30B5XCS2+TXV+ furnace: Y81E100B12LMPS1AHRI reference: 218506755 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640843 → |
CTU30B5XCS2+TXV+ furnace: Y81E100B12SMPS1AHRI reference: 218506752 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640844 → |
CTF30B5ACS2+ furnace: Y81E100B12LMPS1AHRI reference: 218506750 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640845 → |
CTF30B5ACS2+ furnace: Y81E100B12SMPS1AHRI reference: 218506747 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640846 → |
CTU30B5XCS2+TXV+ furnace: Y81E080B12LMPS1AHRI reference: 218506744 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640847 → |
CTU30B5XCS2+TXV+ furnace: Y81E080B12SMPS1AHRI reference: 218506742 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640848 → |
CTF30B5ACS2+ furnace: Y81E080B12LMPS1AHRI reference: 218506739 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640849 → |
CTF30B5ACS2+ furnace: Y81E080B12SMPS1AHRI reference: 218506737 | 15.20 | 7.80 | 8800 | 2.30 | EPA 4640850 → |
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 218506728 | 15.20 | 7.80 | 8900 | 2.34 | EPA 4640851 → |
CTF30B5ACS2+JMC12B2SN1AHRI reference: 218506725 | 15.20 | 7.80 | 8900 | 2.34 | EPA 4640852 → |
CTF24B5ABS2+ furnace: Y81E100B12LMPS1AHRI reference: 218506709 | 15.20 | 7.80 | 8800 | 2.28 | EPA 4640855 → |
CTF24B5ABS2+ furnace: Y81E100B12SMPS1AHRI reference: 218506706 | 15.20 | 7.80 | 8800 | 2.28 | EPA 4640856 → |
CTF24B5ABS2+ furnace: Y81E080B12LMPS1AHRI reference: 218506698 | 15.20 | 7.80 | 8800 | 2.28 | EPA 4640857 → |
CTF24B5ABS2+ furnace: Y81E080B12SMPS1AHRI reference: 218506696 | 15.20 | 7.80 | 8800 | 2.28 | EPA 4640858 → |
CTF24B5ABS2+ furnace: YP9C080B12MP13AHRI reference: 218506693 | 15.20 | 7.80 | 9000 | 2.28 | EPA 4640859 → |
CTF24B5ABS2+ furnace: TP9C080B12MP13AHRI reference: 218506690 | 15.20 | 7.80 | 9000 | 2.28 | EPA 4640860 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.