York / AIR-SOURCE HEAT PUMP

YH2F60TB21

LX SERIES · source records, page 6

177 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for YH2F60TB21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16177 / 177
EER2 · BTU/Wh11–12177 / 177
HSPF2 · BTU/Wh7.8–8.1177 / 177
Cooling capacity · BTU/h53,000–57,000177 / 177
Heating capacity at 47°F / 8.3°C · BTU/h55,000–59,500177 / 177
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000177 / 177
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800177 / 177
COP at 5°F / −15°C2–2.46177 / 177
Equipment / loop typeHP - Split System177 / 177
Refrigerant / source-reported GWPR-410A (GWP:2088)177 / 177
Compressor stagingTwo-stage177 / 177
Connected capabilityNo177 / 177

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21033883615.208.10310002.24EPA 4048468 →
XAFC60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21033883715.208.10310002.24EPA 4048469 →
XAFD60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21033884015.208.10314002.22EPA 4048472 →
XAFD60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21033884215.208.10314002.22EPA 4048473 →
XAHD60JXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21033945015.208.10300002.00EPA 4048474 →
XAHD60JBCN1+ furnace: TM9E100C20MP12AHRI reference: 21033945115.208.10300002.00EPA 4048475 →
XAFD60JXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21033945215.208.10314002.22EPA 4048476 →
XAFD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 21033945315.208.10314002.22EPA 4048477 →
XAFD60JBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21033945615.208.10314002.22EPA 4048480 →
XAFD60JBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21033945715.208.10314002.22EPA 4048481 →
XAFD60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21034004715.208.10314002.22EPA 4048491 →
XAFD60HBCN1+ furnace: TM9E100C20MP12AHRI reference: 21034004815.208.10314002.22EPA 4048492 →
XAHC60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21034005215.208.10308002.02EPA 4048495 →
XAHC60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21034005315.208.10308002.02EPA 4048496 →
XAHC60HXXN1+TXV+ furnace: TM8V120C20MP12AHRI reference: 21034005415.208.10308002.02EPA 4048497 →
XAHC60HXXN1+TXV+ furnace: TM8V100C20MP12AHRI reference: 21034005515.208.10308002.02EPA 4048498 →
XAHC60HXXN1+TXV+ furnace: TMLV120C20MP12AHRI reference: 21034005615.208.10308002.02EPA 4048499 →
XAHC60HBCN1+ furnace: TM8V120C20MP12AHRI reference: 21034006115.208.10308002.02EPA 4048504 →
XAFC60HXXN1+TXV+ furnace: TM9Y100C20MP11AHRI reference: 21033947015.208.10316002.22EPA 4048508 →
XAFC60HBCN1+ furnace: TM9Y100C20MP11AHRI reference: 21033947115.208.10316002.22EPA 4048509 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →