York / AIR-SOURCE HEAT PUMP

YH2F60TB21

LX SERIES · source records, page 2

177 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for YH2F60TB21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 177 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16177 / 177
EER2 · BTU/Wh11–12177 / 177
HSPF2 · BTU/Wh7.8–8.1177 / 177
Cooling capacity · BTU/h53,000–57,000177 / 177
Heating capacity at 47°F / 8.3°C · BTU/h55,000–59,500177 / 177
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000177 / 177
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800177 / 177
COP at 5°F / −15°C2–2.46177 / 177
Equipment / loop typeHP - Split System177 / 177
Refrigerant / source-reported GWPR-410A (GWP:2088)177 / 177
Compressor stagingTwo-stage177 / 177
Connected capabilityNo177 / 177

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD60JBCN1+ furnace: Y81E100C20LMPS1AHRI reference: 21247534215.208.10312002.36EPA 2477941 →
XAFD60JBCN1+ furnace: Y81E080C16LMPS1AHRI reference: 21247534615.208.10314002.42EPA 2477955 →
XAFD60JXXN1+TXV+ furnace: Y81E130D20SMPS1AHRI reference: 21241358615.208.10314002.40EPA 2477957 →
XAHD60JXXN1+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 21247616915.208.10310002.38EPA 2478015 →
XAHD60JXXN1+TXV+ furnace: Y81E130D20LMPS1AHRI reference: 21247533615.208.10310002.38EPA 2478360 →
XAHD60JBCN1+ furnace: Y81E080C20SMPS1AHRI reference: 21241359915.208.10312002.36EPA 2478379 →
XAHD60JXXN1+TXV+ furnace: Y81E080C20LMPS1AHRI reference: 21247617315.208.10312002.36EPA 2478715 →
XAHD60JBCN1+ furnace: Y81E100C16LMPS1AHRI reference: 21247512915.208.10312002.36EPA 2479478 →
XAHD60JBCN1+ furnace: Y81E120C20LMPS1AHRI reference: 21247512415.208.10312002.36EPA 2479537 →
XAHD60JBCN1+ furnace: Y81E130D20SMPS1AHRI reference: 21241358515.208.10310002.38EPA 2479583 →
XAHC60HBCN1+ furnace: Y82E100C20LMPS1AHRI reference: 21241356415.207.80328002.34EPA 2481860 →
XAHD60JXXN1+TXV+ furnace: Y81E130D20SMPS1AHRI reference: 21241358415.208.10310002.38EPA 2481870 →
XAHD60JBCN1+ furnace: Y82E100C16LMPS1AHRI reference: 21241358315.208.10312002.36EPA 2481872 →
XAHD60JBCN1+ furnace: Y82E120C20LMPS1AHRI reference: 21241357915.208.10312002.36EPA 2481873 →
XAFD60JBCN1+ furnace: Y81E130D20SMPS1AHRI reference: 21241358715.208.10314002.40EPA 2481874 →
XAHD60JBCN1+ furnace: Y81E120C16SMPS1AHRI reference: 21241359115.208.10310002.38EPA 2481875 →
XAHD60JXXN1+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 21241359015.208.10310002.38EPA 2481876 →
XAFD60JXXN1+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 21241359215.208.10314002.40EPA 2481877 →
XAHD60JBCN1+ furnace: Y81E120C16LMPS1AHRI reference: 21247617115.208.10310002.38EPA 2482725 →
XAHD60JBCN1+ furnace: Y81E080C20LMPS1AHRI reference: 21247617515.208.10312002.36EPA 2482726 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →