York / AIR-SOURCE HEAT PUMP

YH2F48TB21

LX SERIES · source records, page 2

327 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–47,500BTU/h

Each efficiency range summarizes published EPA records for YH2F48TB21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16327 / 327
EER2 · BTU/Wh10.5–12327 / 327
HSPF2 · BTU/Wh7.8–8.1327 / 327
Cooling capacity · BTU/h44,500–47,500327 / 327
Heating capacity at 47°F / 8.3°C · BTU/h43,500–48,000327 / 327
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200327 / 327
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800327 / 327
COP at 5°F / −15°C2.2–2.84327 / 327
Equipment / loop typeHP - Split System327 / 327
Refrigerant / source-reported GWPR-410A (GWP:2088)327 / 327
Compressor stagingTwo-stage327 / 327
Connected capabilityNo327 / 327

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHC60HBCN1+ furnace: TMLV100C16MP12AHRI reference: 21033928016.008.10246002.48EPA 3025788 →
XAHC60HBCN1+ furnace: YPLC080C16MP13AHRI reference: 21033928316.008.10246002.48EPA 3025791 →
XAHC60HBCN1+ furnace: TPLC080C16MP13AHRI reference: 21033928116.008.10246002.48EPA 3025795 →
XAHC60HBCN1+ furnace: YPLC100C16MP13AHRI reference: 21033928416.008.10246002.48EPA 3025796 →
XAHC60HBCN1+ furnace: TPLC100C16MP13AHRI reference: 21033928216.008.10246002.48EPA 3025797 →
XAHC60HBCN1+ furnace: TM8E080B12MP11AHRI reference: 21033929516.007.80250002.44EPA 3025856 →
XAHC60HBCN1+ furnace: TMLE080B12MP11AHRI reference: 21033929616.007.80250002.44EPA 3025864 →
XAHD60HBCN1+ furnace: TM8E080C16MP11AHRI reference: 21033868816.008.10246002.46EPA 3025869 →
XAHD60HBCN1+ furnace: TMLE080C16MP11AHRI reference: 21033868916.008.10246002.46EPA 3025870 →
XAHD60HBCN1+ furnace: TMLV120C20MP12AHRI reference: 21033864116.008.10248002.46EPA 3025911 →
XAHD60HBCN1+ furnace: TPLC100C20MP13AHRI reference: 21033864216.008.10248002.46EPA 3025927 →
XAHC60HBCN1+ furnace: TMLV120C20MP12AHRI reference: 21033865316.008.10250002.46EPA 3025928 →
XAHD60HBCN1+ furnace: TPLC120C20MP13AHRI reference: 21033864316.008.10248002.46EPA 3025929 →
XAHD60HBCN1+ furnace: YPLC120C20MP13AHRI reference: 21033864516.008.10248002.46EPA 3025931 →
XAHC60HBCN1+ furnace: TPLC100C20MP13AHRI reference: 21033865416.008.10250002.46EPA 3025936 →
XAHD60HBCN1+ furnace: YPLC100C20MP13AHRI reference: 21033864416.008.10248002.46EPA 3025938 →
XAHC60HBCN1+ furnace: YPLC120C20MP13AHRI reference: 21033865716.008.10250002.46EPA 3025940 →
XAHC60HBCN1+ furnace: TPLC120C20MP13AHRI reference: 21033865516.008.10250002.46EPA 3025941 →
XAHC60HBCN1+ furnace: TM8E120C20MP11AHRI reference: 21034058716.008.10250002.44EPA 3026053 →
XAHC60HBCN1+ furnace: TMLE080C16MP11AHRI reference: 21033994316.008.10246002.48EPA 3026067 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.