York / AIR-SOURCE HEAT PUMP

YH2F42TB21

LX SERIES · source records, page 19

449 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for YH2F42TB21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 449 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16449 / 449
EER2 · BTU/Wh11.7–12449 / 449
HSPF2 · BTU/Wh7.8–8.1449 / 449
Cooling capacity · BTU/h39,500–42,000449 / 449
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000449 / 449
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600449 / 449
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600449 / 449
COP at 5°F / −15°C1.98–2.42449 / 449
Equipment / loop typeHP - Split System449 / 449
Refrigerant / source-reported GWPR-410A (GWP:2088)449 / 449
Compressor stagingTwo-stage449 / 449
Connected capabilityNo449 / 449

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FXXN1+TXV+ furnace: TM9Y080C16MP11AHRI reference: 21033906715.207.80196002.00EPA 3986129 →
XAHC48FBCN1+ furnace: TM9Y060B12MP11AHRI reference: 21033907115.207.80192002.00EPA 3986130 →
XAFC48FBCN1+ furnace: TP9C100C16MP13AHRI reference: 21033907715.208.10195002.06EPA 3986131 →
XAFC48FBCN1+ furnace: TM9V100C16MP12AHRI reference: 21033907515.208.10195002.06EPA 3986132 →
XAFC48FXXN1+TXV+ furnace: TM9V100C16MP12AHRI reference: 21033907215.208.10195002.06EPA 3986133 →
XAFC48FXXN1+TXV+ furnace: TP9C100C16MP13AHRI reference: 21033907315.208.10195002.06EPA 3986134 →
XAFC48FXXN1+TXV+ furnace: YP9C100C16MP13AHRI reference: 21033907415.208.10195002.06EPA 3986135 →
XAHC48FBCN1+ furnace: TP9C080B12MP13AHRI reference: 21033908515.208.10195002.06EPA 3986136 →
XAFC48FBCN1+ furnace: YP9C100C16MP13AHRI reference: 21033907915.208.10195002.06EPA 3986137 →
XAHC48FBCN1+ furnace: TM9V080B12MP12AHRI reference: 21033908415.208.10195002.06EPA 3986138 →
XAHC48FBCN1+ furnace: YP9C080B12MP13AHRI reference: 21033908615.208.10195002.06EPA 3986139 →
XAFD48FBCN1+ furnace: TM9E120D20MP12AHRI reference: 21033908815.208.10193002.04EPA 3986140 →
XAHD48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21033909015.208.10198002.12EPA 3986141 →
XAFD48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21033909215.208.10196002.04EPA 3986142 →
XAFC48FXXN1+TXV+ furnace: TL9E080C16UH11AHRI reference: 21033912515.207.80196002.00EPA 3986165 →
XAFC48FBCN1+ furnace: TL9E080C16UH11AHRI reference: 21033912615.207.80196002.00EPA 3986166 →
XAFD48FBCN1+ furnace: TL8E100C20UH11AHRI reference: 21033977615.208.10196002.04EPA 3986482 →
XAFC48FBCN1+ furnace: TL9E100C20UH11AHRI reference: 21033977115.207.80199002.02EPA 3986483 →
XAFC48FXXN1+TXV+ furnace: TL9E100C20UH11AHRI reference: 21033977015.207.80199002.02EPA 3986741 →
XAFD48FBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21034110515.207.80196002.02EPA 3987084 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.