Heating performance & equipment details
Ranges include the 449 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 449 / 449 |
| EER2 · BTU/Wh | 11.7–12 | 449 / 449 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 449 / 449 |
| Cooling capacity · BTU/h | 39,500–42,000 | 449 / 449 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 37,400–41,000 | 449 / 449 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,200–26,600 | 449 / 449 |
| Heating capacity at 5°F / −15°C · BTU/h | 18,400–22,600 | 449 / 449 |
| COP at 5°F / −15°C | 1.98–2.42 | 449 / 449 |
| Equipment / loop type | HP - Split System | 449 / 449 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 449 / 449 |
| Compressor staging | Two-stage | 449 / 449 |
| Connected capability | No | 449 / 449 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFD48FBCN1+ furnace: Y81E100C20SMPS1AHRI reference: 212413451 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2483463 → |
XAFD48FBCN1+ furnace: Y81E100C16SMPS1AHRI reference: 212413460 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2483465 → |
XAFD48FBCN1+ furnace: Y81E100C20LMPS1AHRI reference: 212475264 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2484108 → |
XAFC48FXXN1+TXV+ furnace: Y81E100C20LMPS1AHRI reference: 212475716 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2484755 → |
XAFD48FBCN1+ furnace: Y81E100C16LMPS1AHRI reference: 212476108 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2485052 → |
XAFD48FBCN1+ furnace: Y92E120D20SMPS1AHRI reference: 212413341 | 15.20 | 7.80 | 20800 | 2.18 | EPA 2486122 → |
XAHD48FBCN1+ furnace: Y92E120D20SMPS1AHRI reference: 212413339 | 15.20 | 8.10 | 22600 | 2.32 | EPA 2486124 → |
XAHC48FBCN1+ furnace: Y92E100C16SMPS1AHRI reference: 212413347 | 15.20 | 7.80 | 21600 | 2.32 | EPA 2486140 → |
XAFD48FBCN1+ furnace: Y91E120D20SMPS1AHRI reference: 212413363 | 15.20 | 8.10 | 20800 | 2.24 | EPA 2486145 → |
XAHC48FBCN1+ furnace: Y91E100C16SMPS1AHRI reference: 212413374 | 15.20 | 7.80 | 22200 | 2.32 | EPA 2486148 → |
XAFC48FXXN1+TXV+ furnace: Y81E100C16SMPS1AHRI reference: 212413461 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2486157 → |
XAFC48FBCN1+ furnace: Y81E100C16SMPS1AHRI reference: 212413462 | 15.20 | 8.10 | 21000 | 2.22 | EPA 2486158 → |
XAFC48FBCN1+ furnace: Y81E100B12SMPS1AHRI reference: 212413467 | 15.20 | 7.80 | 21200 | 2.20 | EPA 2486173 → |
XAFC48FXXN1+TXV+ furnace: Y81E100B12SMPS1AHRI reference: 212413466 | 15.20 | 7.80 | 21200 | 2.20 | EPA 2486174 → |
XAFC48FBCN1+ furnace: TMLV100C16MP12AHRI reference: 210338482 | 15.20 | 8.10 | 19200 | 2.02 | EPA 2785584 → |
XAFC48FBCN1+ furnace: TPLC080C16MP13AHRI reference: 210338484 | 15.20 | 8.10 | 19200 | 2.02 | EPA 2785589 → |
XAFC48FBCN1+ furnace: YPLC100C16MP13AHRI reference: 210338490 | 15.20 | 8.10 | 19200 | 2.02 | EPA 2785592 → |
XAFC48FBCN1+ furnace: TPLC100C16MP13AHRI reference: 210338486 | 15.20 | 8.10 | 19200 | 2.02 | EPA 2785597 → |
XAFC48FBCN1+ furnace: YPLC080C16MP13AHRI reference: 210338488 | 15.20 | 8.10 | 19200 | 2.02 | EPA 2785602 → |
XAFD48FBCN1+ furnace: YPLC080C16MP13AHRI reference: 210341172 | 15.20 | 7.80 | 19800 | 2.02 | EPA 2786524 → |