York / AIR-SOURCE HEAT PUMP

HMH72B341

HMH7 · source records, page 27

863 published source records · source checked Sep 21, 2026

SEER2 range15.5–18.5BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,400–35,200BTU/h

Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18.5863 / 863
EER2 · BTU/Wh9–10.5863 / 863
HSPF2 · BTU/Wh8.1–8.5863 / 863
Cooling capacity · BTU/h31,400–35,200863 / 863
Heating capacity at 47°F / 8.3°C · BTU/h31,400–34,800863 / 863
Heating capacity at 17°F / −8.3°C · BTU/h24,600–27,000863 / 863
Heating capacity at 5°F / −15°C · BTU/h22,200–25,000863 / 863
COP at 5°F / −15°C1.8–2.18863 / 863
Equipment / loop typeHP - Split System863 / 863
Refrigerant / source-reported GWPR-410A (GWP:2088)863 / 863
Compressor stagingContinuously variable863 / 863
Connected capabilityNo863 / 863

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFB30CXXN1+TXV+ furnace: TM9E060A10MP12Cold climate designationAHRI reference: 21137796617.008.10236002.00EPA 4598064 →
XAFB30CXXN1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 21137794217.008.10236002.00EPA 4598066 →
XAFC30CXXN1+TXV+ furnace: TM9E060B12MP12Cold climate designationAHRI reference: 21137793117.008.10236002.00EPA 4598067 →
XAHC30CXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21137787317.008.10232001.98EPA 4598073 →
XAFB30CXXN1+TXV+ furnace: YP9C060B12MP13Cold climate designationAHRI reference: 21137780117.008.10236002.02EPA 4598080 →
XAFB30CXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 21137779817.008.10236002.02EPA 4598081 →
XAFB30CXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 21137779517.008.10236002.02EPA 4598082 →
XAFC30CXXN1+TXV+ furnace: YP9C060B12MP13Cold climate designationAHRI reference: 21137776517.008.10236002.02EPA 4598083 →
XAFC30CXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 21137776217.008.10236002.02EPA 4598084 →
XAFC30CXXN1+TXV+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 21137776017.008.10236002.02EPA 4598085 →
XAFB30CXXN1+TXV+ furnace: YP9C080B12MP13Cold climate designationAHRI reference: 21137768417.008.10236002.02EPA 4598092 →
XAFB30CXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21137768217.008.10236002.02EPA 4598093 →
XAFB30CXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21137768117.008.10236002.02EPA 4598094 →
XAFC30CXXN1+TXV+ furnace: YP9C080B12MP13Cold climate designationAHRI reference: 21137765217.008.10236002.02EPA 4598095 →
XAFC30CXXN1+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21137764917.008.10236002.02EPA 4598096 →
XAFC30CXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21137764617.008.10236002.02EPA 4598097 →
XAFC30CXXN1+TXV+ furnace: YP9C080C16MP13Cold climate designationAHRI reference: 21137757817.008.10234002.04EPA 4598104 →
XAFC30CXXN1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 21137757717.008.10234002.04EPA 4598105 →
XAFC30CXXN1+TXV+ furnace: TM9V080C16MP12Cold climate designationAHRI reference: 21137757617.008.10234002.04EPA 4598106 →
XAHC30CXXN1+TXV+ furnace: YP9C100C16MP13Cold climate designationAHRI reference: 21137750617.008.10230002.00EPA 4598110 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →