York / AIR-SOURCE HEAT PUMP

HMH72B341

HMH7 · source records, page 15

863 published source records · source checked Sep 21, 2026

SEER2 range15.5–18.5BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity31,400–35,200BTU/h

Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 863 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–18.5863 / 863
EER2 · BTU/Wh9–10.5863 / 863
HSPF2 · BTU/Wh8.1–8.5863 / 863
Cooling capacity · BTU/h31,400–35,200863 / 863
Heating capacity at 47°F / 8.3°C · BTU/h31,400–34,800863 / 863
Heating capacity at 17°F / −8.3°C · BTU/h24,600–27,000863 / 863
Heating capacity at 5°F / −15°C · BTU/h22,200–25,000863 / 863
COP at 5°F / −15°C1.8–2.18863 / 863
Equipment / loop typeHP - Split System863 / 863
Refrigerant / source-reported GWPR-410A (GWP:2088)863 / 863
Compressor stagingContinuously variable863 / 863
Connected capabilityNo863 / 863

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC30CXXN1+TXV+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 21137752717.508.50232002.06EPA 4586846 →
XAFD48FXXN1+TXV+ furnace: Y82E080C16LMPS1Cold climate designationAHRI reference: 21329670917.508.50232002.08EPA 4587021 →
XAHC36DBCN1+ furnace: Y81E080C16LMPS1Cold climate designationAHRI reference: 21329668517.508.50236002.08EPA 4587025 →
XAHC36DXXN1+TXV+ furnace: Y81E080C16LMPS1Cold climate designationAHRI reference: 21329668317.508.50236002.08EPA 4587026 →
XAHC36DXXN1+TXV+ furnace: Y81E080C16SMPS1Cold climate designationAHRI reference: 21329668217.508.50236002.08EPA 4587027 →
XAHC30CXXN1+TXV+ furnace: Y81E080C16LMPS1Cold climate designationAHRI reference: 21329663817.508.50228002.04EPA 4587031 →
XAHC30CXXN1+TXV+ furnace: Y81E080C16SMPS1Cold climate designationAHRI reference: 21329663717.508.50228002.04EPA 4587032 →
XAHC30CXXN1+TXV+ furnace: Y81E080C20LMPS1Cold climate designationAHRI reference: 21329659317.508.50228002.02EPA 4587041 →
XAHC30CXXN1+TXV+ furnace: Y81E080C20SMPS1Cold climate designationAHRI reference: 21329659217.508.50228002.02EPA 4587042 →
XAHB36DBCN1+JMC12B2SN1Cold climate designationAHRI reference: 21487579817.508.50228002.00EPA 4587070 →
XAHB30CXXN1+TXV+ furnace: TL8E060A12UH11Cold climate designationAHRI reference: 21137891717.508.10230001.98EPA 4598038 →
XAFC30CXXN1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 21137891117.508.50234002.04EPA 4598039 →
XAFB30CXXN1+TXV+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21137887517.508.10236002.00EPA 4598041 →
XAFC30CXXN1+TXV+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21137886417.508.10236002.00EPA 4598042 →
XAFB30CXXN1+TXV+ furnace: TMLV060A12MP12Cold climate designationAHRI reference: 21137843517.508.10234002.02EPA 4598049 →
XAFB30CXXN1+TXV+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 21137843217.508.10234002.02EPA 4598050 →
XAFC30CXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 21137821817.508.50232002.04EPA 4598057 →
XAFC30CXXN1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 21137821517.508.50232002.04EPA 4598058 →
XAFC30CXXN1+TXV+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 21137821217.508.50232002.04EPA 4598059 →
XAFB30CXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21137790317.508.10236002.02EPA 4598070 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →