York / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 19

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS1+ furnace: Y81E120C20SMPS1AHRI reference: 21869762717.008.10350002.26EPA 4684777 →
CTF60D5CGS1+ furnace: Y92E120D20SMPS1AHRI reference: 21869762617.008.10344002.24EPA 4684778 →
CTM60C5CGS1+ furnace: Y91E100C16SMPS1AHRI reference: 21869762217.008.10346002.22EPA 4684782 →
CTM60D5CJS1+ furnace: Y92E120D20SMPS1AHRI reference: 21869760417.008.10390002.24EPA 4684785 →
CTM60D5CJS1+ furnace: Y81E130D20LMPS1AHRI reference: 21869759417.008.10390002.28EPA 4684786 →
CTM60D5CJS1+ furnace: Y81E130D20SMPS1AHRI reference: 21869759317.008.10390002.28EPA 4684787 →
CTF60D5CJS1+ furnace: Y92E120D20SMPS1AHRI reference: 21869759017.008.10390002.26EPA 4684788 →
CTM60D5CJS2+ furnace: Y91E120D20SMPS1AHRI reference: 21864157816.508.10390002.24EPA 4664852 →
CTF60D5CJS2+ furnace: Y91E120D20SMPS1AHRI reference: 21864157716.508.10390002.24EPA 4664853 →
CTM60D5CGS2+ furnace: Y91E120D20SMPS1AHRI reference: 21864154516.508.10352002.26EPA 4664883 →
CTF60D5CGS2+ furnace: Y91E120D20SMPS1AHRI reference: 21864147516.508.10342002.24EPA 4664953 →
CTU60C5XGS2+TXV+ furnace: Y91E100C16SMPS1AHRI reference: 21864145316.508.10346002.22EPA 4664975 →
CTF60C5CGS2+ furnace: Y91E100C16SMPS1AHRI reference: 21864145216.508.10346002.22EPA 4664976 →
CTM60D5CGS2+ furnace: TM9E120D20MP12AHRI reference: 21868817816.508.10350002.24EPA 4679005 →
CTM60C5CGS2+ furnace: TM9E080C20MP12AHRI reference: 21868817716.508.10362002.26EPA 4679006 →
CTF60D5CGS2+ furnace: TM9E120D20MP12AHRI reference: 21868817016.508.10350002.24EPA 4679013 →
CTU60C5XGS2+TXV+ furnace: TM9E100C20MP12AHRI reference: 21868814116.508.10362002.26EPA 4679036 →
CTF60C5CGS2+ furnace: TM9E100C20MP12AHRI reference: 21868814016.508.10362002.26EPA 4679037 →
CTU60C5XGS2+TXV+ furnace: TM9E080C20MP12AHRI reference: 21868813916.508.10362002.26EPA 4679038 →
CTF60C5CGS2+ furnace: TM9E080C20MP12AHRI reference: 21868813816.508.10362002.26EPA 4679039 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →