York / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 10

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS1+ furnace: Y92E100C16SMPS1AHRI reference: 21869769617.508.10350002.24EPA 4684708 →
CTM60C5CGS1+ furnace: Y82E100C20LMPS1AHRI reference: 21869769517.508.10348002.26EPA 4684709 →
CTM60C5CGS1+ furnace: TM9E100C16MP12AHRI reference: 21869769117.508.10354002.22EPA 4684713 →
CTM60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 21869768917.508.10338002.24EPA 4684715 →
CTF60D5CGS1+ furnace: Y81E130D20LMPS1AHRI reference: 21869768417.508.10352002.30EPA 4684720 →
CTF60D5CGS1+ furnace: Y81E130D20SMPS1AHRI reference: 21869768317.508.10352002.30EPA 4684721 →
CTM60C5CGS1+ furnace: Y82E100C16LMPS1AHRI reference: 21869768017.508.10342002.24EPA 4684724 →
CTU60C5XGS1+TXV+ furnace: Y81E120C16LMPS1AHRI reference: 21869767917.508.10346002.26EPA 4684725 →
CTU60C5XGS1+TXV+ furnace: Y81E120C16SMPS1AHRI reference: 21869767817.508.10346002.26EPA 4684726 →
CTF60C5CGS1+ furnace: Y81E120C16LMPS1AHRI reference: 21869767717.508.10346002.26EPA 4684727 →
CTF60C5CGS1+ furnace: Y81E120C16SMPS1AHRI reference: 21869767617.508.10346002.26EPA 4684728 →
CTM60C5CGS1+ furnace: Y82V100C20SMPC1AHRI reference: 21869767517.508.10338002.24EPA 4684729 →
CTU60C5XGS1+TXV+ furnace: Y82V120C20SMPC1AHRI reference: 21869767317.508.10338002.24EPA 4684731 →
CTF60C5CGS1+ furnace: Y82V120C20SMPC1AHRI reference: 21869767217.508.10338002.24EPA 4684732 →
CTU60C5XGS1+TXV+ furnace: Y81E080C16LMPS1AHRI reference: 21869767017.508.10342002.24EPA 4684734 →
CTU60C5XGS1+TXV+ furnace: Y81E080C16SMPS1AHRI reference: 21869766917.508.10342002.24EPA 4684735 →
CTF60C5CGS1+ furnace: Y81E080C16LMPS1AHRI reference: 21869766817.508.10342002.24EPA 4684736 →
CTF60C5CGS1+ furnace: Y81E080C16SMPS1AHRI reference: 21869766717.508.10342002.24EPA 4684737 →
CTU60C5XGS1+TXV+ furnace: Y82E100C16LMPS1AHRI reference: 21869766417.508.10336002.22EPA 4684740 →
CTF60C5CGS1+ furnace: Y82E100C16LMPS1AHRI reference: 21869766317.508.10336002.22EPA 4684741 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →