York / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
JHC60C5CH2SS1AHRI reference: 21859822218.008.10380002.00EPA 4651067 →
JSE60D5CJ2SS1AHRI reference: 21864157118.008.10390002.28EPA 4664859 →
JHC60D5CJ2SS1AHRI reference: 21864157018.008.10390002.28EPA 4664860 →
JSC60D5CJ2SS1AHRI reference: 21864156918.008.10390002.28EPA 4664861 →
JHC48C5CG2SS1Cold climate designationAHRI reference: 21859822317.508.50340002.20EPA 4651066 →
CTF60D5CJS2+ furnace: Y81E130D20LMPS1AHRI reference: 21864158217.508.10390002.28EPA 4664848 →
CTF60D5CJS2+ furnace: Y81E130D20SMPS1AHRI reference: 21864158117.508.10390002.28EPA 4664849 →
CTM60D5CJS2+JMC20D2SN1AHRI reference: 21864157617.508.10385002.26EPA 4664854 →
CTF60D5CJS2+JME18D2SN2AHRI reference: 21864157517.508.10385002.26EPA 4664855 →
CTM60D5CJS2+JME18D2SN2AHRI reference: 21864157417.508.10385002.26EPA 4664856 →
CTF60D5CJS2+JMC20D2SN1AHRI reference: 21864157317.508.10385002.26EPA 4664857 →
JHE60D5CJ2SS2AHRI reference: 21864157217.508.10390002.28EPA 4664858 →
CTM60C5CGS2+ furnace: Y82E100C20LMPS1AHRI reference: 21864156517.508.10348002.26EPA 4664863 →
CTF60D5CGS2+ furnace: Y81E130D20LMPS1AHRI reference: 21864156217.508.10352002.30EPA 4664866 →
CTF60D5CGS2+ furnace: Y81E130D20SMPS1AHRI reference: 21864156117.508.10352002.30EPA 4664867 →
CTU60C5XGS2+TXV+ furnace: Y81E080C16LMPS1AHRI reference: 21864156017.508.10342002.24EPA 4664868 →
CTU60C5XGS2+TXV+ furnace: Y81E080C16SMPS1AHRI reference: 21864155917.508.10342002.24EPA 4664869 →
CTF60C5CGS2+ furnace: Y81E080C16LMPS1AHRI reference: 21864155817.508.10342002.24EPA 4664870 →
CTF60C5CGS2+ furnace: Y81E080C16SMPS1AHRI reference: 21864155717.508.10342002.24EPA 4664871 →
CTM60C5CGS2+ furnace: Y81E080C20LMPS1AHRI reference: 21864155617.508.10346002.26EPA 4664872 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →