HH860E2S11
LX SERIES · source records, page 31
625 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 625 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 625 / 625 |
| EER2 · BTU/Wh | 10–12 | 625 / 625 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 625 / 625 |
| Cooling capacity · BTU/h | 43,500–54,500 | 625 / 625 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 625 / 625 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 625 / 625 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 625 / 625 |
| COP at 5°F / −15°C | 2–2.1 | 625 / 625 |
| Equipment / loop type | HP - Split System | 625 / 625 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 625 / 625 |
| Compressor staging | Continuously variable | 625 / 625 |
| Connected capability | No | 625 / 625 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CGS2+ furnace: TM9V080C16MP12AHRI reference: 218505311 | 17.00 | 9.00 | 33600 | 2.00 | EPA 4641065 → |
CTU60D5XHS1+TXVAHRI reference: 217334752 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4469652 → |
CTU60D5XGS1+TXVCold climate designationAHRI reference: 217334756 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4469653 → |
CTU60C5XGS1+TXVCold climate designationAHRI reference: 217334757 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4469654 → |
CTM60C5CHS1AHRI reference: 214606530 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497291 → |
CTF60C5CHS1AHRI reference: 214606531 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497292 → |
CTM60D5CGS1Cold climate designationAHRI reference: 214606583 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497327 → |
CTM60D5CHS1AHRI reference: 214606582 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497328 → |
CTF60C5CGS1Cold climate designationAHRI reference: 214606581 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497329 → |
CTF60D5CHS1AHRI reference: 214606580 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4497330 → |
CTF60D5CGS1Cold climate designationAHRI reference: 214606579 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497331 → |
CTM60C5CGS1Cold climate designationAHRI reference: 214606584 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4497332 → |
CTF60D5CJS1Cold climate designationAHRI reference: 214606578 | 15.20 | 8.50 | 40000 | 2.00 | EPA 4575826 → |
CTM60D5CJS1Cold climate designationAHRI reference: 214606519 | 15.20 | 8.50 | 40000 | 2.00 | EPA 4575840 → |
CTU60C5XGS2+TXVCold climate designationAHRI reference: 218574265 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649842 → |
CTM60C5CGS2Cold climate designationAHRI reference: 218574261 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649846 → |
CTM60D5CGS2Cold climate designationAHRI reference: 218574260 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649847 → |
CTM60D5CHS2AHRI reference: 218574259 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4649848 → |
CTF60C5CGS2Cold climate designationAHRI reference: 218574258 | 15.20 | 8.50 | 34200 | 2.00 | EPA 4649849 → |
CTF60D5CHS2AHRI reference: 218574257 | 15.20 | 8.10 | 40000 | 2.00 | EPA 4649850 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →