HH860E2S11
LX SERIES · source records, page 20
625 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 625 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 625 / 625 |
| EER2 · BTU/Wh | 10–12 | 625 / 625 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 625 / 625 |
| Cooling capacity · BTU/h | 43,500–54,500 | 625 / 625 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 625 / 625 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 625 / 625 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 625 / 625 |
| COP at 5°F / −15°C | 2–2.1 | 625 / 625 |
| Equipment / loop type | HP - Split System | 625 / 625 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 625 / 625 |
| Compressor staging | Continuously variable | 625 / 625 |
| Connected capability | No | 625 / 625 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS1+TXV+ furnace: TM8V100C20MP12Cold climate designationAHRI reference: 214719800 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3738958 → |
CTU60C5XGS1+TXV+ furnace: TMLV120C20MP12Cold climate designationAHRI reference: 214719801 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3738961 → |
CTU60C5XGS1+TXV+ furnace: TM9E100C16MP12Cold climate designationAHRI reference: 214719807 | 18.00 | 9.00 | 34400 | 2.00 | EPA 3738970 → |
CTF60C5CGS1+ furnace: Y82V080C16SMPC1Cold climate designationAHRI reference: 217443924 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044837 → |
CTM60C5CGS1+ furnace: Y82V100C16SMPC1Cold climate designationAHRI reference: 217443923 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044838 → |
CTU60C5XGS1+TXV+ furnace: Y82V080C16SMPC1Cold climate designationAHRI reference: 217443925 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044839 → |
CTF60C5CGS1+ furnace: Y82V100C16SMPC1Cold climate designationAHRI reference: 217443927 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044840 → |
CTM60C5CGS1+ furnace: Y82V080C16SMPC1Cold climate designationAHRI reference: 217443926 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044841 → |
CTU60C5XGS1+TXV+ furnace: Y82V100C16SMPC1Cold climate designationAHRI reference: 217443928 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044842 → |
CTF60C5CGS1+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 217443929 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044843 → |
CTF60C5CGS1+ furnace: Y82V120C20SMPC1Cold climate designationAHRI reference: 217443931 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044844 → |
CTU60C5XGS1+TXV+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 217443930 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044845 → |
CTU60C5XGS1+TXV+ furnace: Y82V120C20SMPC1Cold climate designationAHRI reference: 217443932 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044846 → |
CTM60C5CGS1+ furnace: Y82V120C20SMPC1Cold climate designationAHRI reference: 217443934 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044847 → |
CTM60C5CGS1+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 217443933 | 18.00 | 9.00 | 32600 | 2.00 | EPA 4044849 → |
CTM60C5CGS1+ furnace: Y92E100C20SMPS1Cold climate designationAHRI reference: 216374533 | 18.00 | 9.00 | 33800 | 2.00 | EPA 4047153 → |
CTF60C5CGS1+ furnace: Y92E100C20SMPS1Cold climate designationAHRI reference: 216374522 | 18.00 | 9.00 | 33000 | 2.00 | EPA 4047161 → |
CTU60C5XGS1+TXV+ furnace: Y92E100C20SMPS1Cold climate designationAHRI reference: 216374523 | 18.00 | 9.00 | 33000 | 2.00 | EPA 4047162 → |
CTF60C5CGS1+ furnace: Y92E080C16SMPS1Cold climate designationAHRI reference: 216374524 | 18.00 | 9.00 | 32800 | 2.00 | EPA 4047163 → |
CTU60C5XGS1+TXV+ furnace: Y92E080C16SMPS1Cold climate designationAHRI reference: 216374525 | 18.00 | 9.00 | 32800 | 2.00 | EPA 4047164 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →