HH860E2S11
LX SERIES · source records, page 17
625 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 625 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 625 / 625 |
| EER2 · BTU/Wh | 10–12 | 625 / 625 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 625 / 625 |
| Cooling capacity · BTU/h | 43,500–54,500 | 625 / 625 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 625 / 625 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 625 / 625 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 625 / 625 |
| COP at 5°F / −15°C | 2–2.1 | 625 / 625 |
| Equipment / loop type | HP - Split System | 625 / 625 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 625 / 625 |
| Compressor staging | Continuously variable | 625 / 625 |
| Connected capability | No | 625 / 625 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60D5XGS1+TXV+ furnace: Y81E130D20SMPS1Cold climate designationAHRI reference: 214650319 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3477397 → |
CTU60D5XGS1+TXV+ furnace: TM9Y120D20MP11Cold climate designationAHRI reference: 214650591 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477400 → |
CTU60D5XGS1+TXV+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 214650029 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477423 → |
CTU60D5XGS1+TXV+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 214650034 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477424 → |
CTU60D5XGS1+TXV+ furnace: YP9C120D20MP13Cold climate designationAHRI reference: 214650038 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3477425 → |
CTU60D5XGS1+TXV+ furnace: Y91E120D20SMPS1Cold climate designationAHRI reference: 214650133 | 18.00 | 9.00 | 34200 | 2.00 | EPA 3477431 → |
CTM60D5CGS1+JMET18DS2N1Cold climate designationAHRI reference: 214421501 | 18.00 | 9.50 | 33800 | 2.00 | EPA 3477507 → |
CTU60C5XGS1+TXV+ furnace: TP9C100C16MP13Cold climate designationAHRI reference: 214807644 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3557649 → |
CTU60C5XGS1+TXV+ furnace: YP9C100C16MP13Cold climate designationAHRI reference: 214807645 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3557650 → |
CTU60C5XGS1+TXV+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 214807658 | 18.00 | 9.00 | 33600 | 2.00 | EPA 3557661 → |
CTU60C5XGS1+TXV+ furnace: Y81E100C20SMPS1Cold climate designationAHRI reference: 214807659 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3557663 → |
CTU60C5XGS1+TXV+ furnace: Y81E120C16SMPS1Cold climate designationAHRI reference: 214807660 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3557666 → |
CTU60C5XGS1+TXV+ furnace: Y81E100C16SMPS1Cold climate designationAHRI reference: 214807661 | 18.00 | 9.00 | 33200 | 2.00 | EPA 3557669 → |
CTU60C5XGS1+TXV+ furnace: Y81E080C16SMPS1Cold climate designationAHRI reference: 214807664 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3557672 → |
CTU60C5XGS1+TXV+ furnace: Y91E100C20SMPS1Cold climate designationAHRI reference: 214807666 | 18.00 | 9.00 | 34000 | 2.00 | EPA 3557674 → |
CTU60C5XGS1+TXV+ furnace: Y91E080C20SMPS1Cold climate designationAHRI reference: 214807667 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3557675 → |
CTU60C5XGS1+TXV+ furnace: Y91E080C16SMPS1Cold climate designationAHRI reference: 214807668 | 18.00 | 9.00 | 33800 | 2.00 | EPA 3557676 → |
CTU60C5XGS1+TXV+ furnace: Y81E120C20SMPS1Cold climate designationAHRI reference: 214807608 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3557802 → |
CTU60C5XGS1+TXV+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 214807609 | 18.00 | 9.00 | 33400 | 2.00 | EPA 3557804 → |
CTU60C5XGS1+JMVT17CC2N1+TXVCold climate designationAHRI reference: 214807611 | 18.00 | 9.00 | 33000 | 2.00 | EPA 3557806 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →