HH860E2S11
LX SERIES · source records, page 11
625 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 625 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 625 / 625 |
| EER2 · BTU/Wh | 10–12 | 625 / 625 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 625 / 625 |
| Cooling capacity · BTU/h | 43,500–54,500 | 625 / 625 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 43,500–56,000 | 625 / 625 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–39,000 | 625 / 625 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–40,500 | 625 / 625 |
| COP at 5°F / −15°C | 2–2.1 | 625 / 625 |
| Equipment / loop type | HP - Split System | 625 / 625 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 625 / 625 |
| Compressor staging | Continuously variable | 625 / 625 |
| Connected capability | No | 625 / 625 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CHS2+ furnace: Y92E100C20SMPS1AHRI reference: 218502828 | 19.00 | 8.50 | 39000 | 2.00 | EPA 4639698 → |
CTF60D5CJS2+ furnace: YP9C120D20MP13AHRI reference: 218502825 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4639699 → |
CTF60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 218502822 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4639700 → |
CTF60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 218502819 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4639701 → |
CTF60D5CJS2+JMC20D2SN1AHRI reference: 218502816 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4639702 → |
CTF60D5CJS2+JMVT20DC2N1AHRI reference: 218502813 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4639703 → |
CTF60D5CJS2+ furnace: Y81E130D20LMPS1AHRI reference: 218502810 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4639704 → |
CTF60D5CJS2+ furnace: Y81E130D20SMPS1AHRI reference: 218502808 | 19.00 | 9.00 | 39000 | 2.00 | EPA 4639705 → |
CTF60D5CHS2+ furnace: Y92E120D20SMPS1AHRI reference: 218502797 | 19.00 | 9.00 | 40000 | 2.00 | EPA 4639708 → |
CTF60D5CHS2+JMC20D2SN1AHRI reference: 218502792 | 19.00 | 8.50 | 38000 | 2.00 | EPA 4639710 → |
CTF60D5CHS2+JMVT20DC2N1AHRI reference: 218502786 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4639712 → |
CTF60D5CHS2+ furnace: YP9C120D20MP13AHRI reference: 218502774 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4639716 → |
CTF60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 218502771 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4639717 → |
CTF60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 218502768 | 19.00 | 9.00 | 39500 | 2.00 | EPA 4639718 → |
CTF60D5CHS2+ furnace: Y91E120D20SMPS1AHRI reference: 218502763 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4639720 → |
CTF60D5CHS2+ furnace: Y81E130D20LMPS1AHRI reference: 218502755 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4639723 → |
CTF60D5CHS2+ furnace: Y81E130D20SMPS1AHRI reference: 218502753 | 19.00 | 9.00 | 38500 | 2.00 | EPA 4639724 → |
CTF60C5CHS2+ furnace: Y92E100C20SMPS1AHRI reference: 218502749 | 19.00 | 8.50 | 39000 | 2.00 | EPA 4639725 → |
CTF60C5CHS2+JMVT17CC2N1AHRI reference: 218502746 | 19.00 | 9.00 | 38000 | 2.00 | EPA 4639726 → |
CTF60C5CHS2+ furnace: YP9C100C20MP13AHRI reference: 218502743 | 19.00 | 8.50 | 38500 | 2.00 | EPA 4639727 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →