HH836E2S12
LX SERIES · source records, page 20
669 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 669 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 669 / 669 |
| EER2 · BTU/Wh | 10–11.7 | 669 / 669 |
| HSPF2 · BTU/Wh | 8.5 | 669 / 669 |
| Cooling capacity · BTU/h | 31,200–34,000 | 669 / 669 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,000–34,000 | 669 / 669 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,600–34,200 | 669 / 669 |
| Heating capacity at 5°F / −15°C · BTU/h | 26,800–28,200 | 669 / 669 |
| COP at 5°F / −15°C | 2.18–2.38 | 669 / 669 |
| Equipment / loop type | HP - Split System | 669 / 669 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 669 / 669 |
| Compressor staging | Two-stage | 669 / 669 |
| Connected capability | No | 669 / 669 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5CDS1+ furnace: Y81E120C16SMPS1Cold climate designationAHRI reference: 218697229 | 17.00 | 8.50 | 27600 | 2.28 | EPA 4683639 → |
CTM36C5CDS1+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 218697516 | 17.00 | 8.50 | 27800 | 2.28 | EPA 4684799 → |
CTF36C5CDS1+ furnace: YPLC100C16MP13Cold climate designationAHRI reference: 218697513 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684802 → |
CTF36C5CDS1+ furnace: YPLC080C16MP13Cold climate designationAHRI reference: 218697512 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684803 → |
CTF36C5CDS1+ furnace: TPLC100C16MP13Cold climate designationAHRI reference: 218697511 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684804 → |
CTF36C5CDS1+ furnace: TPLC080C16MP13Cold climate designationAHRI reference: 218697510 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684805 → |
CTF36C5CDS1+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 218697509 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684806 → |
CTF36C5CDS1+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 218697508 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684807 → |
CTF36C5CDS1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 218697507 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4684808 → |
CTU48C5XFS1+TXV+ furnace: Y81E080C20LMPS1Cold climate designationAHRI reference: 218697503 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4684811 → |
CTU48C5XFS1+TXV+ furnace: Y81E080C20SMPS1Cold climate designationAHRI reference: 218697502 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4684812 → |
CTF48C5CFS1+ furnace: Y81E080C20LMPS1Cold climate designationAHRI reference: 218697501 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4684813 → |
CTF48C5CFS1+ furnace: Y81E080C20SMPS1Cold climate designationAHRI reference: 218697500 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4684814 → |
CTU48C5XFS1+TXV+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 218697499 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4684815 → |
CTF48C5CFS1+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 218697498 | 17.00 | 8.50 | 27000 | 2.34 | EPA 4684816 → |
CTF36C5CDS1+ furnace: Y81E120C20LMPS1Cold climate designationAHRI reference: 218697489 | 17.00 | 8.50 | 27800 | 2.28 | EPA 4684825 → |
CTF36C5CDS1+ furnace: Y81E120C20SMPS1Cold climate designationAHRI reference: 218697488 | 17.00 | 8.50 | 27800 | 2.28 | EPA 4684826 → |
CTM36B5CDS1+ furnace: Y82V080B12SMPC1Cold climate designationAHRI reference: 218697486 | 17.00 | 8.50 | 27400 | 2.24 | EPA 4684828 → |
CTU48C5XFS1+TXV+ furnace: YPLC100C16MP13Cold climate designationAHRI reference: 218697484 | 17.00 | 8.50 | 27000 | 2.30 | EPA 4684830 → |
CTU48C5XFS1+TXV+ furnace: YPLC080C16MP13Cold climate designationAHRI reference: 218697483 | 17.00 | 8.50 | 27000 | 2.30 | EPA 4684831 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →