York / AIR-SOURCE HEAT PUMP

HH836E2S12

LX SERIES · source records, page 2

669 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.5BTU/Wh
Cooling capacity31,200–34,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 669 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18669 / 669
EER2 · BTU/Wh10–11.7669 / 669
HSPF2 · BTU/Wh8.5669 / 669
Cooling capacity · BTU/h31,200–34,000669 / 669
Heating capacity at 47°F / 8.3°C · BTU/h32,000–34,000669 / 669
Heating capacity at 17°F / −8.3°C · BTU/h32,600–34,200669 / 669
Heating capacity at 5°F / −15°C · BTU/h26,800–28,200669 / 669
COP at 5°F / −15°C2.18–2.38669 / 669
Equipment / loop typeHP - Split System669 / 669
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)669 / 669
Compressor stagingTwo-stage669 / 669
Connected capabilityNo669 / 669

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS2+JME12C2SN2Cold climate designationAHRI reference: 21864186017.508.50270002.34EPA 4664645
CTM48C5CFS2+JMC17C2SN1Cold climate designationAHRI reference: 21864185417.508.50268002.36EPA 4664651
CTM48C5CFS2+ furnace: Y82E100C20LMPS1Cold climate designationAHRI reference: 21864185317.508.50270002.34EPA 4664652
CTM48C5CFS2+JMC16C2SN1Cold climate designationAHRI reference: 21864185217.508.50268002.36EPA 4664653
CTU48C5XFS2+JMC17C2SN1+TXVCold climate designationAHRI reference: 21864185117.508.50268002.36EPA 4664654
CTF48C5CFS2+JMC17C2SN1Cold climate designationAHRI reference: 21864185017.508.50268002.36EPA 4664655
CTU48C5XFS2+JMC16C2SN1+TXVCold climate designationAHRI reference: 21864184917.508.50268002.38EPA 4664656
CTF48C5CFS2+JMC16C2SN1Cold climate designationAHRI reference: 21864184817.508.50268002.38EPA 4664657
CTU48C5XFS2+JME16C2SN2+TXVCold climate designationAHRI reference: 21864184717.508.50270002.34EPA 4664658
CTF48C5CFS2+JME16C2SN2Cold climate designationAHRI reference: 21864184617.508.50270002.34EPA 4664659
CTF36C5CDS2+ furnace: Y82V080C16SMPC1Cold climate designationAHRI reference: 21864183517.508.50276002.28EPA 4664674
CTF36C5CDS2+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 21864183417.508.50276002.28EPA 4664675
CTM36C5CDS2+ furnace: Y82V080C16SMPC1Cold climate designationAHRI reference: 21864182717.508.50276002.28EPA 4664682
CTM36C5CDS2+ furnace: Y82V100C20SMPC1Cold climate designationAHRI reference: 21864182617.508.50276002.28EPA 4664683
CTF36C5CDS2+ furnace: Y82E120C20LMPS1Cold climate designationAHRI reference: 21864181817.508.50272002.24EPA 4664691
CTF36C5CDS2+ furnace: Y82V100C16SMPC1Cold climate designationAHRI reference: 21864181617.508.50276002.30EPA 4664693
CTU36B5XDS2+TXV+ furnace: Y82V080B12SMPC1Cold climate designationAHRI reference: 21864180517.508.50274002.26EPA 4664704
CTF36B5CDS2+ furnace: Y82V080B12SMPC1Cold climate designationAHRI reference: 21864180417.508.50274002.26EPA 4664705
CTF36C5CDS2+ furnace: Y82E100C16LMPS1Cold climate designationAHRI reference: 21864180117.508.50280002.32EPA 4664708
CTF36C5CDS2+ furnace: Y81E080C16LMPS1Cold climate designationAHRI reference: 21864180017.508.50280002.32EPA 4664709

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →